Radiation dose at cardiac computed tomography: facts and fiction.
نویسندگان
چکیده
Cardiac computed tomography (CT) dosimetry makes use of two radiation parameters: a volume CT dose index (CTDI) and a dose length product (DLP). The volume CTDI quantifies the intensity of the radiation used to perform CT examinations, whereas DLP quantifies the amount of radiation used. CTDI metrics can be converted into patient dose metrics by using dose/CTDI conversion factors. In cardiac CT imaging, these need to take into account the x-ray tube voltage, scan length, and scan region, as well as patient size. Organ doses to patients in cardiac CT can be converted into cancer risks when patient demographic factors are taken into account. A risk analysis of patients undergoing cardiac CT angiography at our institution showed that a majority (62%) were males, with a median age of approximately 60 years and a median weight of approximately 90 kg. The median DLP was approximately 1100 mGy cm, corresponding to an effective dose of approximately 29 mSv in normal-sized patients. The average patient lifetime risk for a radiation-induced cancer was estimated to be 0.12%, with 85% of it attributed to lung cancer. Patients with an age and weight at the 10th percentile, who also received a DLP at the 90th percentile, would have cancer risk estimates approximately double the average value. Radiation risks are required to determine whether examinations are indicated, defined as examinations in which individual patient benefit exceeds corresponding patient risk. Understanding radiation risks in cardiac CT encourages operators to use the least amount of radiation to achieve satisfactory diagnostic performance.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملEstimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria
Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملLocal Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of thoracic imaging
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2010