Performance of the automated motion correction program for the calculation of left ventricular volume and ejection fraction using quantitative gated SPECT software.

نویسندگان

  • Kiyoshi Uchiyama
  • Tatsuro Kaminaga
  • Mitsuo Waida
  • Masami Yasuda
  • Takashi Chikamatsu
چکیده

The effectiveness of the automated motion correction software (INSTILL, Philips Medical Systems Co. Ltd., Andover, USA) proposed by Matsumoto et al. to prevent motion artifact in quantitative gated SPECT, was tested with a technetium-99m point source and cardiac phantom. INSTILL well corrected the error due to point source movement during acquisition up to a distance of 5 pixels (32.8 mm) in the right and caudal directions, as well as with a distance of up to 7 pixels (45.9 mm) of oblique (caudal-right 45 degree) movement inside the coronal plane. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were also well adjusted with INSTILL, for up to 3 pixels (19.7 mm) movement of the dynamic cardiac phantom during acquisition in the right, caudal and oblique directions. The respective maximum error with one, two and three pixel movement was 9, 24 and 23 ml in EDV, and 8, 22 and 21 ml in ESV. The maximum error of EF was 3% in all conditions without INSTILL. After using INSTILL, the maximum residual errors of both EDV and ESV were 7 ml and that of EF was 3% in all conditions. Quantitative gated SPECT software with INSTILL will calculate EDV, ESV and EF against movement of patients in the coronal plane. INSTILL is therefore concluded to be a reliable software for motion correction in clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2005