High-throughput analysis of chemical components and theoretical ethanol yield of dedicated bioenergy sorghum using dual-optimized partial least squares calibration models
نویسندگان
چکیده
BACKGROUND Due to its chemical composition and abundance, lignocellulosic biomass is an attractive feedstock source for global bioenergy production. However, chemical composition variations interfere with the success of any single methodology for efficient bioenergy extraction from diverse lignocellulosic biomass sources. Although chemical component distributions could guide process design, they are difficult to obtain and vary widely among lignocellulosic biomass types. Therefore, expensive and laborious "one-size-fits-all" processes are still widely used. Here, a non-destructive and rapid analytical technology, near-infrared spectroscopy (NIRS) coupled with multivariate calibration, shows promise for addressing these challenges. Recent advances in molecular spectroscopy analysis have led to methodologies for dual-optimized NIRS using sample subset partitioning and variable selection, which could significantly enhance the robustness and accuracy of partial least squares (PLS) calibration models. Using this methodology, chemical components and theoretical ethanol yield (TEY) values were determined for 70 sweet and 77 biomass sorghum samples from six sweet and six biomass sorghum varieties grown in 2013 and 2014 at two study sites in northern China. RESULTS Chemical components and TEY of the 147 bioenergy sorghum samples were initially analyzed and compared using wet chemistry methods. Based on linear discriminant analysis, a correct classification assignment rate (either sweet or biomass type) of 99.3% was obtained using 20 principal components. Next, detailed statistical analysis demonstrated that partial optimization using sample set partitioning based on joint X-Y distances (SPXY) for sample subset partitioning enhanced the robustness and accuracy of PLS calibration models. Finally, comparisons between five dual-optimized strategies indicated that competitive adaptive reweighted sampling coupled with the SPXY (CARS-SPXY) was the most efficient and effective method for improving predictive performance of PLS multivariate calibrations. CONCLUSIONS As a dual-optimized methodology, sample subset partitioning combined with variable selection is an efficient and straightforward strategy to enhance the accuracy and robustness of NIRS models. This knowledge should facilitate generation of improved lignocellulosic biomass feedstocks for bioethanol production. Moreover, methods described here should have wider applicability for use with feedstocks incorporating multispecies biomass resource streams.
منابع مشابه
Rapid analysis of composition and reactivity in cellulosic biomass feedstocks with near-infrared spectroscopy
BACKGROUND Obtaining accurate chemical composition and reactivity (measures of carbohydrate release and yield) information for biomass feedstocks in a timely manner is necessary for the commercialization of biofuels. Our objective was to use near-infrared (NIR) spectroscopy and partial least squares (PLS) multivariate analysis to develop calibration models to predict the feedstock composition a...
متن کاملSimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملSpectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
متن کاملDetermination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares
The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کامل