Automated detection of breast mass spiculation levels and evaluation of scheme performance.

نویسندگان

  • Luan Jiang
  • Enmin Song
  • Xiangyang Xu
  • Guangzhi Ma
  • Bin Zheng
چکیده

RATIONALE AND OBJECTIVES Although the spiculation levels of breast mass boundaries are a primary sign of malignancy for masses detected on mammography, developing an automated computerized method to detect spiculation levels and quantitatively evaluating the performance of such a method is a difficult task. The objectives of this study were to (1) develop and test a new method to improve mass segmentation and detect mass boundary spiculation levels and (2) assess the performance of this method using a relatively large imaging data set. MATERIALS AND METHODS The fully automated method developed for this study includes three image-processing steps. In the first step, the principle of maximum entropy is applied in the selected region of interest (ROI) after correcting the background trend to enhance the initial outlines of a mass. In the second step, an active-contour model is used to refine the initial outlines. In the third step, spiculated lines connected to the mass boundary are detected and identified using a special line detector. A quantitative spiculation index is computed to assess the degree of spiculation. To develop and evaluate this automated method, 211 ROIs depicting masses were extracted from a publicly available image database. Among these ROIs, 106 depicted circumscribed mass regions and 105 involved spiculated mass regions. The performance of the method was evaluated using receiver-operating characteristic (ROC) analysis. RESULTS The computed area under the ROC curve, when applying the method to the data set, was 0.701 +/- 0.027. By setting up a threshold at a spiculation index of 5.0, the method achieved an overall classification accuracy of 66.4%, with 54.3% sensitivity and 78.3% specificity. CONCLUSIONS In this study, a new computerized method with a number of unique characteristics was developed to detect spiculated mass regions, and a simple spiculation index was applied to quantify mass spiculation levels. Although this quantitative index can be used to distinguish between spiculated and circumscribed masses, the results also suggest that the automated detection of mass spiculation levels remains a technical challenge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interactive computer-aided diagnosis of breast masses: computerized selection of visually similar image sets from a reference library.

RATIONALE AND OBJECTIVES The clinical utility of interactive computer-aided diagnosis (ICAD) systems depends on clinical relevance and visual similarity between the queried breast lesions and the ICAD-selected reference regions. The objective of this study is to develop and test a new ICAD scheme that aims improve visual similarity of ICAD-selected reference regions. MATERIALS AND METHODS A l...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

Automated detection method for architectural distortion areas on mammograms based on morphological processing and surface analysis

As well as mass and microcalcification, architectural distortion is a very important finding for the early detection of breast cancer via mammograms, and such distortions can be classified into three typical types: spiculation, retraction, and distortion. The purpose of this work is to develop an automatic method for detecting areas of architectural distortion with spiculation. The suspect area...

متن کامل

روشی جدید به منظور تعیین مرز ضایعات در تصاویر فراصوت از بافت پستان: اصلاح وفقی ضریب انتشار ناهمسانگرد

Accurate segmentation plays a vital role in automated analysis of ultrasonic images. A new method based on adaptive anisotropic diffusion is introduced here for lesion detection in ultrasonic images of the breast. In this method, a hypothesis testing framework is defined first to separate lesions from healthy breast tissue. Then the boundary of lesion is estimated by adaptive anisotropic diffus...

متن کامل

Breast abnormalities segmentation using the wavelet transform coefficients aggregation

Introduction: Breast cancer is the most common cancer among women in the world. The automatic detection of masses in digital mammograms is a challenging task and a major step in the development of breast cancer CAD systems. In this study, we introduce a new method for automatic detection of suspicious mass candidate (SMC) regions in a mammogram. Methods: Mammography is widely used for the early...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Academic radiology

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 2008