Favorable results in patients with small size CarboMedics heart valves in the aortic position.
نویسندگان
چکیده
Hemodynamic performance of the CarboMedics heart valve in the aortic position and its clinical impacts were investigated in 126 consecutive patients. The actuarial survival rates of patients who had undergone isolated aortic valve replacement and concomitant aortic and mitral valve replacement were 82.6+/-5.7% and 71.0+/-9.2% at 8 years, respectively. Morbid events were rare, and almost all late survivors were free from evident cardiac symptoms regardless of the valve size. Echocardiography revealed suboptimal transvalvular pressure gradients and effective orifice areas of 19 mm and 21 mm valves. However, relief of the left ventricular overload and improvement of the clinical symptoms as well as cardiac function were comparable to those of patients with larger valves. Valve function measured by echocardiography did not show significant correlation to late outcome. Good results can be expected even in the presence of echocardiographic data such as peak pressure gradient over 40 mmHg, effective orifice area less than 1.0 cm(2), and effective orifice area index less than 0.7 cm(2)/m(2).
منابع مشابه
مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملMechanical heart valves: 50 years of evolution.
The past 50 years have witnessed remarkable progress in the development of safe, hemodynamically favorable mechanical heart valves. Starr-Edwards aortic and mitral ball valves introduced in the mid-1960s, continue to be used successfully worldwide. More than 100,000 Omniscience and Omnicarbon tilting-disc valves have been implanted since 1978 with essentially no mechanical failure; similar resu...
متن کاملFive-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.
BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...
متن کاملLeaflet arrest in St Jude Medical and CarboMedics valves: an experimental study.
OBJECTIVE Two patients who suffered acute failure of their St Jude Medical Masters aortic valve prostheses due to leaflet arrest that were unrelated to suture material are presented. It was hypothesized that the valves failed because force applied to bear upon the valve annulus caused the hinge mechanism to become restricted or to arrest. METHODS A study was designed to measure the force that...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2001