Domain Wall Motion in the Presence of Nuclear Spins
نویسندگان
چکیده
We investigate the motion of a domain wall in the presence of a dynamical hyperfine field. At temperature T high compared to the hyperfine coupling, the nuclear spins create a spatially random potential landscape, with dynamics dictated by the nuclear relaxation time T2. The distribution of the domain wall relaxation times (both in the thermal and quantum regimes) can show a long tail, characteristic of stochastic processes where rare events are important. Here, these are due to occasional strong fluctuations in the nuclear spin polarisation. PACS numbers: 75.45.+j
منابع مشابه
Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]
It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...
متن کاملThe value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]
Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...
متن کاملEmploying Internal Flexible Wall as Mass Absorber in Tanks Subjected to Harmonic Excitations
The possibility of employing internal wall as mass absorber in rectangular water storage tanks subjected to harmonic ground motion excitation is investigated in this paper. Internal walls are used in these tanks usually for service performance purposes, which could be used as mass absorber to control seismic demand on tank's exterior walls. Derivation of the response of the coupled system inclu...
متن کاملGated myocardial perfusion SPECT in patients with left bundle block but having low probability of coronary artery disease; as compared to the patients with normal electrocardiogram
Introduction: We aimed to investigate of effect of left bundle branch block (LBBB) on perfusion and functional parameters in dipyridamole Tc99m-MIBI gated myocardial perfusion SPECT which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 70 patients with low pre-test probability of coronary artery disease in two groups: 35 patients with LBBB and 35 subject...
متن کاملPULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW
Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...
متن کامل