Accuracy of EuroSCORE II in patients undergoing minimally invasive mitral valve surgery.
نویسندگان
چکیده
OBJECTIVES EuroSCORE II has been implemented with the view to providing better performance than the previous logistic EuroSCORE. However, until now, no external validations have been carried out in the minimally invasive context. Therefore, we sought to validate the accuracy of EuroSCORE II in a retrospective series of consecutive patients undergoing minimally invasive mitral valve surgery. METHODS Data of 1609 consecutive patients who underwent minimally invasive mitral valve surgery in our institution were retrospectively reviewed. The accuracy of EuroSCORE II was assessed in terms of discrimination and calibration. Discrimination was tested via analysis of the area under the curve of receiver operator characteristic; calibration was achieved by calculating the observed versus expected mortality ratio and the Hosmer-Lemeshow test for test probability; global accuracy was assessed by using Brier's score; results were compared with the previous logistic EuroSCORE version. EuroSCORE II performance was also tested for discrimination of postoperative complications. Discrimination subgroup analysis was carried out for single surgeon results, and for high-risk patients those outliers were defined after boxplot analysis (EuroSCORE II ≥6%). RESULTS EuroSCORE II showed good discrimination power (area under the curve 0.846), and was statistically superior to logistic EuroSCORE (P = 0.01). In terms of calibration, both EuroSCORE II and logistic over-predicted mortality; with regard to adverse events, the discrimination of EuroSCORE II was adequate for acute renal failure, low-output syndrome and increased intensive care unit stay; area under the curve of receiver operating characteristic for high-risk patients with EuroSCORE ≥6% was suboptimal (0.654); single surgeon results did not influence the discrimination of EuroSCORE II. CONCLUSIONS EuroSCORE II showed good discrimination power in our series of minimally invasive mitral valve patients; however, it over-predicted mortality. Individual performance did not influence discrimination. Performance was suboptimal for prediction of complications and for high-risk subgroup in-hospital mortality.
منابع مشابه
Minimally invasive versus conventional mitral valve surgery: a propensity-matched comparison.
OBJECTIVE Less invasive approaches to mitral valve surgery are increasingly used for improved cosmesis; however, few studies have investigated their effect on outcome. We sought to compare these minimally invasive approaches fairly with conventional full sternotomy by using propensity-matching methods. METHODS From January 1995 to January 2004, 2124 patients underwent isolated mitral valve su...
متن کاملValidation of EuroSCORE II in a modern cohort of patients undergoing cardiac surgery.
OBJECTIVE We aimed to validate the new EuroSCORE II risk model in a contemporary cardiac surgery practice in the United Kingdom (UK). METHODS The original logistic EuroSCORE was compared to EuroSCORE II with regard to accuracy of predicting in-hospital mortality. Analysis was performed on isolated coronary artery bypass grafts (CABG; n = 2913), aortic valve replacement (AVR; n = 814), mitral ...
متن کاملMinimally invasive redo mitral valve surgery without aortic crossclamp.
INTRODUCTION Reoperations of the mitral valve have a higher rate of complications when compared with the first surgery. With the field of video-assisted techniques for the first surgery of mitral valve became routine, reoperation cases began to arouse interest for this less invasive procedures. OBJECTIVE To assess the results and the technical difficulties in 10 patients undergoing minimally ...
متن کاملOutcomes of minimally invasive valve surgery versus median sternotomy in patients age 75 years or greater.
BACKGROUND Advanced age is a major predictor of poor outcome in patients undergoing valve surgery. We hypothesized that elderly patients who underwent minimally invasive valve surgery for aortic or mitral valve disease would do better when compared with those undergoing the standard median sternotomy. METHODS We retrospectively reviewed 2,107 consecutive heart operations at our institution an...
متن کاملAntegrade and retrograde arterial perfusion strategy in minimally invasive mitral-valve surgery: a propensity score analysis on 1280 patients.
OBJECTIVES Recent studies have suggested an increased risk of stroke in patients undergoing minimally invasive mitral-valve surgery with retrograde perfusion when compared with antegrade perfusion. The aim of the present study was therefore to evaluate the impact on early outcome of retrograde arterial perfusion (RAP) strategy vs antegrade arterial perfusion strategy in a consecutive large coho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2015