pH electrode performance under automated management conditions
نویسندگان
چکیده
pH is frequently measured in laboratories, but to have confidence in the results it is necessary to know that it was measured properly. For an electrode to give accurate results it must be treated well and calibrated correctly. In this paper, an automated system for pH measurement is described; the system uses the operational pH scale and calibrates using two or three buffer solutions, taking proper account of the effects of temperature on the system. The system can be programmed with standard methods and procedures to ensure that the electrode gives the best possible performance. Calibrations and measurements within the system are reproducible, and the automated system is more robust than the manual pH meter, and requires less operator time.
منابع مشابه
Flow Injection Potentiometric Assay of Hexoprenaline in Its Pure State, Pharmaceutical Preparations, and Biological Samples
Different hexoprenaline (Hx(2)SO(4)) conventional and coated wire electrodes were constructed and evaluated. Membranes were based on hexoprenalinium phosphotungstate (Hx-PTA) and hexporenalinium phosphomolybdate (Hx-PMA). The electrodes were fully characterized in terms of their composition, response time, life span, pH, and temperature and then were applied to the potentiometric determination ...
متن کاملElectrochemical Behavior of 2-Aminothiazole at Poly Glycine Modified Pencil Graphite Electrode
Electro analysis of 2-Aminothiazole (2-AT) by a low cost poly Glycine modified Pencil Graphite Electrode (poly Gly/PGE) was studied using of cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. The optimal experimental conditions to determine 2-AT was setup by the variation of the current with scan rate, concentration and pH. Electrochemical performance of the 2-AT at ...
متن کاملبهینهسازی فرایند انعقاد الکتریکی در تصفیه فاضلاب نساجی با استفاده از روش سطح پاسخ
Background and objectives: Electrocoagulation (EC) as an electrochemical method was developed to overcome the drawbacks of conventional decolorization technologies and is an attractive alternative for the treatment of textile dyes. This study was aimed at the optimization of the EC process for decolorization and COD removal of a real textile wastewater using response surface methodology (RSM). ...
متن کاملDesign and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملDesign and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 19 شماره
صفحات -
تاریخ انتشار 1997