Intraindividual variation of glycohemoglobin: implications for interpretation and analytical goals.

نویسندگان

  • G Phillipou
  • P J Phillips
چکیده

Intraindividual variation (CVi) for glycohemoglobin (GHb) was estimated from serial measurements in patients with diabetes in either stable or variable clinical control. GHb determinations were performed by an affinity column procedure with an analytical imprecision of 4.9% (weighted average; GHb 8.2-14.7%). Within the groups of patients, both a short- (28-32 days) and long-term (approximately 85 days) sampling protocol was used. The derived CVi for each category was 4.2% (n = 16, stable, short-term), 7.1% (n = 23, stable, long-term), 5.1% (n = 13, variable, short-term), and 9.8% (n = 21, variable, long-term). The mean GHb within each category was similar (approximately 11%), and there was no statistically significant difference in GHb values between categories. The results establish that the CVi for GHb is affected by both clinical control and the sampling time interval. These findings have important implications for the estimation of significant differences between serial GHb measurements and the setting of appropriate analytical precision goals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Analytical Goals for Hemoglobin A1c Measurement in IFCC Units and National Glycohemoglobin Standardization

The variation of a biological measurand can be expressed in the units of the measured concentrations or as a percentage of the absolute variation relative to the mean concentration. For example, given that different metrologic systems are in use for the measurement of human body temperature, this parameter can be expressed in degrees Celsius (Europe), degrees Fahrenheit (US), or degrees Kelvin ...

متن کامل

The Analytical Goals for Hemoglobin A1c Measurement in IFCC Units and National Glycohemoglobin Standardization

The variation of a biological measurand can be expressed in the units of the measured concentrations or as a percentage of the absolute variation relative to the mean concentration. For example, given that different metrologic systems are in use for the measurement of human body temperature, this parameter can be expressed in degrees Celsius (Europe), degrees Fahrenheit (US), or degrees Kelvin ...

متن کامل

Analytical and biologic variability in measures of hemostasis, fibrinolysis, and inflammation: assessment and implications for epidemiology.

An increasing number of cardiovascular epidemiologic studies are measuring non-traditional risk markers of disease, most of which do not have established biovariability characteristics. When biovariability data have been reported, they usually represent a short time period, and, in any case, there is little consensus on how the information should be used. The authors performed a long-term (6-mo...

متن کامل

Influence of biological and analytical variation on urine measurements for monitoring exposure to cadmium.

OBJECTIVE To define the mean intraindividual biological variation in urinary concentrations of cadmium and retinol binding protein (RBP) in untimed, random urine samples and the influence of creatinine or specific gravity correction on reducing this variation. The relation between biological variation and analytical variation in defining uncertainty in a single measurement and significant diffe...

متن کامل

Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 11 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1993