Minimax optimization for handling range and setup uncertainties in proton therapy.
نویسندگان
چکیده
PURPOSE Intensity modulated proton therapy (IMPT) is sensitive to errors, mainly due to high stopping power dependency and steep beam dose gradients. Conventional margins are often insufficient to ensure robustness of treatment plans. In this article, a method is developed that takes the uncertainties into account during the plan optimization. METHODS Dose contributions for a number of range and setup errors are calculated and a minimax optimization is performed. The minimax optimization aims at minimizing the penalty of the worst case scenario. Any optimization function from conventional treatment planning can be utilized by the method. By considering only scenarios that are physically realizable, the unnecessary conservativeness of other robust optimization methods is avoided. Minimax optimization is related to stochastic programming by the more general minimax stochastic programming formulation, which enables accounting for uncertainties in the probability distributions of the errors. RESULTS The minimax optimization method is applied to a lung case, a paraspinal case with titanium implants, and a prostate case. It is compared to conventional methods that use margins, single field uniform dose (SFUD), and material override (MO) to handle the uncertainties. For the lung case, the minimax method and the SFUD with MO method yield robust target coverage. The minimax method yields better sparing of the lung than the other methods. For the paraspinal case, the minimax method yields more robust target coverage and better sparing of the spinal cord than the other methods. For the prostate case, the minimax method and the SFUD method yield robust target coverage and the minimax method yields better sparing of the rectum than the other methods. CONCLUSIONS Minimax optimization provides robust target coverage without sacrificing the sparing of healthy tissues, even in the presence of low density lung tissue and high density titanium implants. Conventional methods using margins, SFUD, and MO do not utilize the full potential of IMPT and deliver unnecessarily high doses to healthy tissues.
منابع مشابه
Clinical Implementation of Robust Optimization for Craniospinal Irradiation
With robust optimization for spot scanning proton therapy now commercially available, the ability exists to account for setup, range, and interfield uncertainties during optimization. Robust optimization is particularly beneficial for craniospinal irradiation (CSI) where the large target volume lends itself to larger setup uncertainties and the need for robust match lines can all be handled wit...
متن کاملAn Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning
PURPOSE Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefo...
متن کاملIncluding robustness in multi-criteria optimization for intensity-modulated proton therapy.
We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database of plans each emphasizing different treatment planning objectives, is pre-com...
متن کاملMonte Carlo calculation of proton ranges in water phantom for therapeutic energies
Introduction: One crucial point when calculating the distribution of doses with ions is the uncertainty of the Bragg peak. The proton ranges in determined geometries like homogeneous phantoms and detector geometries can be calculated with a number of various parameterization models. Several different parameterizations of the range-energy relationship exist, with different level...
متن کاملSU-E-T-624: Comparison of PTV+PRV-Based Optimization and Robust Optimization in Intensity-Modulated Proton Therapy.
PURPOSE Robust optimization leads to IMPT plans that are more robust than and superior in optimality compared to PTV-based optimized plans. Robust optimization incorporates setup and range uncertainties, which implicitly adds margins to targets and organs-at-risk (OARs); whereas PTV-based optimization only considers setup uncertainties and adds margins only to targets in practice. The purpose o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 38 3 شماره
صفحات -
تاریخ انتشار 2011