“In vitro” wear behavior of extracoronal precision attachments
نویسندگان
چکیده
The objective of this study was to evaluate the retentive ability and weight change of two extracoronal attachments after repeated insertion/removal cycles. Material and methods: Two extracoronal attachments were used, one with plastic inserts and the other one with conventional metal-alloy. Initial retentive ability was checked under a 20kgf load cell at 5mm/min. The weight of the fi xed/removable pairs was verifi ed with an electronic mass comparator. Fixed/removable pairs were tested with an insertion/removal cycling machine, for 5800 cycles (corresponding to 5 years) at a speed of 32 rpm speed. Insertion/ removal cycles were performed under artifi cial saliva. Weight change and retentive ability of attachments were verifi ed at baseline, six-month, one-year, two-year, three-year, four-year and fi ve-year time intervals. The two-way ANOVA for repeated measurements test was used to verify possible interactions between precision attachment type and retentive ability/weight change over time. Statistically signifi cant associations were found between attachment type and retentive ability over time (P=0.006). Metal-alloy group showed signifi cant differences between baseline and fi rst year (P=0.005), baseline and second year (P=0.001), and between baseline and fi ve years (P=0.035) of insertion/removal cycles. In the plastic insert group, no signifi cant differences were found over time. No statistically signifi cant associations were found between precision attachment types and weight change over time (P=0.643). Initial retentive ability can not be standardized for both attachments; the metal-alloy showed better performance than the plastic insert after fi ve years. Both attachments did not show weight change after fi ve years of simulated use.
منابع مشابه
Full Mouth Rehabilitation with Fixed and Removal Prosthesis using Extracoronal Attachments: A Clinical Report
Full mouth rehabilitation always claims careful attention and meticulous treatment planning. It becomes more challenging with the partial edentulism where bilateral segment is found missing. Successful restoration can be done with plenty of contemporary and conventional treatment planning. Attachment retained partial dentures are one such kind of treatment modality in prosthodontics. Studies ha...
متن کاملCombined Prosthesis with Extracoronal Castable Precision Attachments
Satisfactory restoration in a patient with a partially edentulous situation can be challenging especially when unilateral or bilateral posterior segment of teeth is missing. Successful restoration can be done with various conventional and contemporary treatment options. One such treatment modality is attachment-retained cast partial dentures. This paper describes a case report of a patient with...
متن کاملEnhanced retention of a maxillofacial prosthetic obturator using precision attachments: Two case reports
The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while mai...
متن کاملPrecision attachments for aesthetics and function: a case report.
Successful restoration of the dentition requires plenty of contemporary and conventional treatment techniques and planning and attachment retained partial dentures are one such kind of treatment modality in prosthodontics. Limited space for extracoronal attachments is a serious gap in the design and the fabrication of a precision attachment Removable Partial Denture (RPD). A custom semi-precisi...
متن کاملThree-dimensional finite element analysis of two kinds of extracoronal attachments in a new design to restore maxillary edentulous jaw
Objective: To choose a kind of more reasonable attachment by comparing three-dimensional finite element stresses of two kinds of attachments in anterior implant fixed bridge and posterior extracoronal attachment denture to restore maxillary edentulous jaw. Materials and Methods: The three-dimensional finite element model of extracoronal resilient attachment model (model I) was reconstructed whi...
متن کامل