Comparison of twenty three nebulizer/compressor combinations for domiciliary use.

نویسندگان

  • E C Smith
  • J Denyer
  • A H Kendrick
چکیده

We have assessed the physical and dynamic characteristics of 23 home jet nebulizer/compressor combinations currently available in the UK and Europe. The combinations were evaluated in terms of pressure-flow characteristics, aerosol mass distribution, volume output, electrical costs, and sound level. In addition, we determined the effect of nebulizer fill volume on aerosol mass distribution and volume output. One nebulizer was used with six different compressors, and four compressors were tested with three different nebulizers. The pressure-flow relationships showed a wide variation between models, as did flow-rate at the nebulizer (range 3.0-8.0 L.min-1). The mean +/- SD volume nebulized after 10 min using an initial fill volume of 2.5 and 5.0 mL was 46 +/- 9 and 34 +/- 12%, respectively. The mass median aerodynamic diameter (MMAD) over a 5 min nebulization ranged 2.6 to 10.2 microns. Nine of the nebulizations produced an MMAD of less than 5 microns at both fill volumes. Changing nebulizer/compressor combinations affected flow rate, MMAD and volume output. Sound levels varied between models. Running costs were low, with all using less than 74 kilowatt hours of energy per year. We conclude that there is a wide variation in performance of nebulizer/compressor combinations for use with nebulized bronchodilators. Correct matching of the nebulizer/compressor is seen to be important to ensure optimum performance.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extending the Performance of an Existing Breath-Actuated Nebulizer for Domiciliary Use: Initial Data

The AeroEclipse® BAN (Trudell Medical International (TMI), London, Canada) was initially developed for use in the hospital environment, optimized for medication delivery using air or oxygen supplied at 50 psig pressure (2, 3). This article describes initial laboratory data with a version (AeroEclipse-XL®) optimized for operation by either table-top (OmbraTM table-top compressor, TMI, 230V AC ve...

متن کامل

In vitro delivery of budesonide from 30 jet nebulizer/compressor combinations using infant and child breathing patterns.

BACKGROUND An aerosol of budesonide inhalation suspension is delivered when used with various jet-nebulizer/compressor combinations. The constant introduction of new nebulizer/compressor combinations raises the question of whether the performance of these match the performance of existing devices. The aim of this study was to determine in vitro the inhaled mass and aerosol characteristics of bu...

متن کامل

Characterization of a human powered nebulizer compressor for resource poor settings

BACKGROUND Respiratory disease accounts for three of the ten leading causes of death worldwide. Many of these diseases can be treated and diagnosed using a nebulizer. Nebulizers can also be used to safely and efficiently deliver vaccines. Unfortunately, commercially available nebulizers are not designed for use in regions of the world where lung disease is most prevalent: they are electricity-d...

متن کامل

Terbutaline as powder inhalation from Bricanyl Turbuhaler compared to terbutaline as nebulizer solution in severe chronic airways obstruction.

Twenty two adults with severe chronic airways obstruction--FEV1 from 14 to 57% of predicted--participated on two consecutive days in an open cross over comparison of inhalation of 2 mg terbutaline powder by Bricanyl Turbuhaler and 5 mg terbutaline by a conventional jet nebulizer (Pari Inhalierboy). All participants were domiciliary users of nebulized terbutaline previous to inclusion in this st...

متن کامل

Terbutaline inhalations by the Turbuhaler as replacement for domiciliary nebulizer therapy in severe chronic obstructive pulmonary disease.

Patients with chronic obstructive pulmonary disease (COPD) are often treated with high dose inhalations of beta 2-agonists. We compared domiciliary therapy with terbutaline administered by the Turbuhaler and by a jet nebulizer. Forty nebulizer users with severe COPD were included in the randomized, double-blind, cross-over study. Terbutaline was inhaled t.i.d. for 2 weeks as dry powder (5 doses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 8 7  شماره 

صفحات  -

تاریخ انتشار 1995