Clinical Image Quality Assessment of CS-Reconstructed Brain Images

نویسندگان

  • S. D. Sharma
  • C. Fong
  • B. Tzung
  • K. S. Nayak
چکیده

coronal T2 coronal FLAIR SOS 12.8/13.6 12.5/11.4 2x 14.8/17.3 14.5/13.2 3x 19.8/24.8 14.8/12.5 4x 22.9/25.8 16.1/14.3 Table 1: SNR (reader1/reader2) coronal T2 coronal FLAIR SOS 2.9/3.0 2.7/2.9 2x 2.8/2.6 2.1/2.2 3x 2.3/2.4 1.4/1.9 4x 2.0/2.0 1.1/1.3 Table 3: average qualitative scoring (reader1/reader2); (scoring: 1-poorly defined, 2-seen, 3-well defined); (green-diagnostic quality; yellowsome of diagnostic quality; red-none of diagnostic quality) coronal T2 coronal FLAIR SOS 8.2/7.3 3.9/1.7 2x 10.9/10.1 5.0/2.8 3x 12.9/13.1 6.1/3.2 4x 15.6/14.7 6.8/3.6 Table 2: CNR (reader1/reader2) Figure 1: SOS T2 (left), FLAIR (right) Clinical Image Quality Assessment of CS-Reconstructed Brain Images

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Qualitative evaluation of filter function in brain SPECT [Persian]

Introduction: Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Methods: Forty five patient’s data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz...

متن کامل

A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Compressed sensing MRI combined with SENSE in partial k-space.

Compressed sensing (CS), parallel imaging and partial Fourier (PF) acquisition are all effective methods to reduce k-space sampling and therefore accelerate MR acquisition. The combined use of these methods gives us more options to balance the needs for scan speed and image quality. We conducted simulations on full k-space data to demonstrate the potential use of combining CS-SENSE with PF acqu...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009