Analysis of the fixation quality of cementless hip prostheses using a vibrational technique
نویسندگان
چکیده
Vibration analysis can be used as a more sensitive alternative to conventional techniques for the detection of loosening of total hip replacement (THR) components. The vibration modes of the human femur and of selected THR prosthetic stems were studied by experimental modal analysis using a CADA-X system and by finite element simulation using MARC/Mentat software. Two hypotheses were formulated: (1) the differences between the vibrational behaviour of an intact femur and of the system formed by a femur and an implanted prosthesis will increase with increasing complexity of the mode shapes of the system; (2) when a prosthesis is implanted in a femur, the vibration modes of the prosthesis will be more affected by this interaction than the modes of the femur. After confirming these hypotheses, a method for peroperative assessment of the fixation quality of a THR stem was derived, based on the frequency shifts of the vibration modes of the system.
منابع مشابه
Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملIn vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.
Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovi...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملCemented, cementless, and hybrid prostheses for total hip replacement: cost effectiveness analysis
OBJECTIVE To compare the cost effectiveness of the three most commonly chosen types of prosthesis for total hip replacement. DESIGN Lifetime cost effectiveness model with parameters estimated from individual patient data obtained from three large national databases. SETTING English National Health Service. PARTICIPANTS Adults aged 55 to 84 undergoing primary total hip replacement for oste...
متن کاملCementless Hydroxyapatite Coated Hip Prostheses
More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical e...
متن کامل