Diagnosis of root cause for oscillations in closed-loop chemical process systems
نویسندگان
چکیده
Oscillations in process plants degrade the performance of control loops resulting in poor product quality. Therefore, plant-wide oscillation diagnosis is an essential task to maintain the performance of control loops. In recent years, significant research has been performed on plant-wide oscillation diagnosis. It has been reported that the three major causes for oscillations in linear closed-loop Single-Input Single-Output (SISO) systems are: (i) aggressively tuned controller, (ii) stiction in control valves and, (iii) external disturbances. Several offline data-driven methods have been developed to address the diagnosis problem by focusing on only one of the causes for oscillations. In the current study, an offline data driven approach is developed to identify all the three major causes for oscillations. This approach has the following two components: (i) parametric Hammerstein model based stiction detection and, (ii) non-parametric Hilbert-Huang spectrum analysis for distingusihing between improperly tuned controller and disturbance caused oscillations. Simulation and industrial case studies demonstrate the efficacy of the proposed method for plant-wide oscillation diagnosis.
منابع مشابه
برانگیختگی و میرایی نوسانات عرضی در حلقههای تاج توسط پدیده ویک
Transversal oscillation of coronal loops that are interpreted as signatures of magneto hydrodynamics (MHD) waves are observed frequently in active region corona loops. The amplitude of this oscillation has been found to be strongly attenuated. The damping of transverse oscillation may be produced by the dissipation mechanism and the wake of the traveling disturbance. The damping of transversal ...
متن کاملA New Approach in Preliminary Design of Closed Loop Solar Thermal Systems (RESEARCH NOTE)
In this paper, a model for closed loop solar system is presented and an attempt is made to generalize the model to be utilized for primary design of any solar active thermal system. This model may be used for systems in which gas or a liquid are fluids that flow. Two new parameters, namely, the system heat delivery factor and the system heat absorption factor are introduced in the model. These ...
متن کاملImpact of government’s policies on competition of two closed-loop and regular supply chains
With progressing technologies and new features of production, new products compete with older ones in markets. Indeed, new products initiate contest with olden ones and this process repeats in different productions lifetime several times. In this situation recycling the olden products seems to be significant for supply chains. Governments often levy special tariffs for these products as a contr...
متن کاملAdaptive fuzzy pole placement for stabilization of non-linear systems
A new approach for pole placement of nonlinear systems using state feedback and fuzzy system is proposed. We use a new online fuzzy training method to identify and to obtain a fuzzy model for the unknown nonlinear system using only the system input and output. Then, we linearized this identified model at each sampling time to have an approximate linear time varying system. In order to stabilize...
متن کاملDelay-Scheduled Controllers for Inter-Area Oscillations Considering Time Delays
Unlike the existing views that was introduced the existence of delay caused by the transmission of wide area measurement system data (WAMS) into the controllers input of the power oscilation damping (POD) by communication networks as a reason for poor performance of the POD controllers. This paper shows that the presence of time delay in the feedback loop may improve the performance of a POD co...
متن کامل