Assessment of pulse rate variability by the method of pulse frequency demodulation

نویسندگان

  • Junichiro Hayano
  • Allan Kardec Barros
  • Atsunori Kamiya
  • Nobuyuki Ohte
  • Fumihiko Yasuma
چکیده

BACKGROUND Due to its easy applicability, pulse wave has been proposed as a surrogate of electrocardiogram (ECG) for the analysis of heart rate variability (HRV). However, its smoother waveform precludes accurate measurement of pulse-to-pulse interval by fiducial-point algorithms. Here we report a pulse frequency demodulation (PFDM) technique as a method for extracting instantaneous pulse rate function directly from pulse wave signal and its usefulness for assessing pulse rate variability (PRV). METHODS Simulated pulse wave signals with known pulse interval functions and actual pulse wave signals obtained from 30 subjects with a trans-dermal pulse wave device were analyzed by PFDM. The results were compared with heart rate and HRV assessed from simultaneously recorded ECG. RESULTS Analysis of simulated data revealed that the PFDM faithfully demodulates source interval function with preserving the frequency characteristics of the function, even when the intervals fluctuate rapidly over a wide range and when the signals include fluctuations in pulse height and baseline. Analysis of actual data revealed that individual means of low and high frequency components of PRV showed good agreement with those of HRV (intraclass correlation coefficient, 0.997 and 0.981, respectively). CONCLUSION The PFDM of pulse wave signal provides a reliable assessment of PRV. Given the popularity of pulse wave equipments, PFDM may open new ways to the studies of long-term assessment of cardiovascular variability and dynamics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Welding of titanium base alloys by tungsten-gas pulse arc process (PCGTAW) and investigation of frequency effect on microstructure and mechanical properties

In this research, Ti-6Al-4V alloy sheet with a thickness of one millimeter with butt joint design was welded by tungsten-gas arc welding process using pulse current (PCGTAW) and using AMS 4954G filler metal. In this study, the effect of pulse system frequency on microstructure and mechanical properties was investigated by optical microscopy, Vickers hardness and tensile strength tests. In the n...

متن کامل

Welding of titanium base alloys by tungsten-gas pulse arc process (PCGTAW) and investigation of frequency effect on microstructure and mechanical properties

In this research, Ti-6Al-4V alloy sheet with a thickness of one millimeter with butt joint design was welded by tungsten-gas arc welding process using pulse current (PCGTAW) and using AMS 4954G filler metal. In this study, the effect of pulse system frequency on microstructure and mechanical properties was investigated by optical microscopy, Vickers hardness and tensile strength tests. In the n...

متن کامل

Preliminary Design of Spacecraft Attitude Control with Pulse-Width Pulse-Frequency Modulator for Rest-to-Rest Maneuvers

In this paper, the preferred region of design parameters for quasi-normalized equations of single-axis attitude control of rigid spacecraft using pulse-width pulse-frequency modulator (PWPFM) is presented for rest-to-rest maneuvers. Using the quasi-normalized equations for attitude control reduces the system parameters, that is, the moment of inertia, the filter gain, and the maximum torque of ...

متن کامل

A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability

In this study, we investigated the difference between heart rate variability (HRV) derived from electrocardiogramic(ECG) signals and pulse rate variability (PRV) derived from photoplethysmographic(PPG) signals. Fourteen healthy subjects conducted the protocol: 10 min physiological signals including distal pulse wave on finger and ear from photoplethysmography (PPG), and heart beat from electroc...

متن کامل

Optimization of the Pulsed Gas Tungsten Arc Welding in Dissimilar Joining Austenitic Stainless Steel AISI 316L to Nickel-Base Super Alloy of Monel 400

In this research, optimization of the pulsed gas tungsten arc welding including pulse current, background current, pulse frequency and on time were investigated in welding of non-similar materials of austenitic stainless steel AISI 316L and nickel-base super alloy of Monel 400 by using ERNiCr3 filler metal. In order to obtain optimum conditions of welding the Taguchi method with the L9 array wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2005