Why fat is bright in RARE and fast spin-echo imaging.

نویسندگان

  • R M Henkelman
  • P A Hardy
  • J E Bishop
  • C S Poon
  • D B Plewes
چکیده

Fast spin-echo (FSE) sequences are becoming popular for T2-weighted clinical imaging because they result in a severalfold reduction in imaging time and because they provide conventional spin-echo contrast for most tissues. Fat, however, has been observed to have anomalously high signal intensity on FSE images. The present study shows that the brighter fat results from the multiple 180 degrees refocusing pulses, which eliminate diffusion-mediated susceptibility dephasing and suppress J-coupling modulation of the echo train.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-42: MRI Evaluation of Congenital Uterine Anomalies

Mullerian duct anomalies are an uncommon but often treatable cause of infertility. Patients with müllerian duct anomalies are known to have a higher incidence of infertility, repeated first-trimester spontaneous abortions, fetal intrauterine growth retardation, fetal malposition, preterm labor, and retained placenta. The role of imaging is to help detect, diagnose, and distinguish surgically co...

متن کامل

Fat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.

PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...

متن کامل

Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: initial clinical experience.

OBJECTIVE Reliable, uniform fat suppression is important. Multiple approaches currently exist, many of which suffer from either suboptimal signal-to-noise ratio (SNR), or the inability to obtain consistent fat suppression around the ankle joint. Our purpose was to test iterative decomposition of water and fat with echo asymmetry and the least-squares estimation (IDEAL) method in combination wit...

متن کامل

Density matrix simulations of the effects of J coupling in spin echo and fast spin echo imaging.

A computer simulation has been used to calculate the effects of J coupling on the amplitudes of echoes produced by CPMG sequences. The program computes the evolution of the density matrix for different pulse intervals and can predict the signals obtainable from spin systems of any size and complexity. Results from the simulation confirm the prediction that a decrease in the effects of J couplin...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 2 5  شماره 

صفحات  -

تاریخ انتشار 1992