Measurements on 25 kV Traction Power Supply Systems

نویسندگان

  • R. de Graaff
  • A. van Deursen
  • H. Smulders
  • G. van Alphen
چکیده

At the moment 25 kV traction power supply systems are being introduced in the Netherlands. Currently in the Netherlands a 1500 V DC system is used, however due to increasing energy demands this system is no longer sufficient. For the high-speed lines and heavy freight lines, which are under construction, the 2x25 kV AC system has been chosen. Introduction of this new technology leads to differences compared to the existing systems. Of particular interest are EMC topics such as influence of the traction power supply system on signalling systems, or systems in the close vicinity of the railway system. The latter is especially important in the Netherlands where the railway system runs through densely populated areas. A part of the first Dutch 25 kV line, the “Havenspoorlijn”, connecting the Rotterdam Harbour with the hinterland, will be used as a Pilot-Project. This line will be equipped with several measurement systems, to validate the system design. This project is financed by NS Railinfrabeheer. Preliminary measurements have been performed on the 25 kV system of the Luxembourg Railways, in a way similar to earlier experiments along a TGV track near Lyon, France. Prerequisite for measurements is that the normal traffic is not disturbed, and that the EMC of the system complies with the harsh EM conditions in the very close neighbourhood of the railway. Special techniques and sensors have been developed which allow measurement of current distributions, voltages and magnetic fields, without hampering the normal traffic. Measurements have been performed on a 25 kV RT system and a 25 kV AT system. For the RT system the measurements were done during normal traffic conditions. For the AT system the measurements were done during the daytime with the normal schedule. During the night a light engine was used, and different switching configurations of the supply system could be created.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Quality Analysis in Electric Traction System with Three-phase Induction Motors

Three-phase induction motors are widely used in electric traction systems. Impacts of the traction vehicle equipped by three-phase induction motors on power quality are much different from the impacts of vehicles with DC traction motors. In this paper, the effects of the traction vehicle operation with threephase induction motors on power quality in 110 kV transmission network are investigated....

متن کامل

Modified Bi-directional AC/DC Power Converter with Power Factor Correction

Most existing power  converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...

متن کامل

Power Quality Improvement in Traction Power Supply Networks

AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...

متن کامل

A Novel Ground Fault Identification Method for 2 × 5 kV Railway Power Supply Systems

The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation bet...

متن کامل

Fault Diagnosis of Metro Traction Power Systems Using A Modified Fuzzy Reasoning Spiking Neural P System

This paper presents the application of a modified fuzzy reasoning spiking neural P systems (MFRSN P system, for short) to fault diagnosis of metro traction power supply systems. In MFRSN P systems, three types of neurons are used to represent operation information of protection devices including protective relays and circuit breakers; a reasoning algorithm associated with MFRSN P systems is int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000