Measurement of combined corneal, internal, and total ocular optical quality analysis in anterior segment pathology with the OPD-scan and OPD-station.
نویسندگان
چکیده
PURPOSE To show the clinical use of the NIDEK OPD-Scan wavefront aberrometer and OPD-Station software in anterior segment surgery and pathology. METHODS Case examples are presented along with discussion about the relevant clinical data obtained from the OPD-Scan and OPD-Station software. RESULTS Six case examples including cataract surgery, secondary IOL implantation, phakic intraocular lens surgery, pterygium surgery, contact lens fitting, and multifocal ablations are discussed. CONCLUSIONS A complete understanding of the optics of the eye facilitates a better clinical comprehension of a variety of conditions in anterior segment surgery and pathology.
منابع مشابه
Interpretation of aberrometry measurements in cataract surgery.
PURPOSE To discuss the use of wavefront measurements generated from the NIDEK OPD-Scan II and OPD-Station for cataract surgery. METHODS Case examples are presented along with information and relevant clinical data obtained from the OPD-Scan II aberrometer and OPD-Station software. All eyes underwent corneal topography, wavefront aberrometry, autorefraction, keratometry, and pupillometry measu...
متن کاملPrecision of NIDEK OPD-scan measurements.
PURPOSE To evaluate the repeatability of wavefront measurements using the NIDEK OPD-Scan. METHODS A total of 179 eyes from 90 healthy volunteers (57 women and 33 men) with no corneal or lenticular pathology and normal visual acuity were enrolled in this study. Mean patient age was 39 years (range: 17 to 85 years). All patients underwent four consecutive measurements by one examiner with the N...
متن کاملInternal aberrations and optical quality after femtosecond laser anterior capsulotomy in cataract surgery.
PURPOSE To compare ocular and internal aberrations after femtosecond laser anterior capsulotomy and continuous curvilinear capsulorrhexis in cataract surgery. METHODS In this prospective study, anterior capsulotomy was performed during cataract surgery with an intraocular femtosecond (FS) laser (Alcon LenSx Inc) in 48 eyes. As a control group, continuous curvilinear capsulorrhexis (CCC) was p...
متن کاملThe use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation.
PURPOSE To present case examples outlining the use of wavefront aberrometry for toric intraocular lens (IOL) implantation pre- and postoperatively. METHODS Twelve eyes that underwent AcrySof Toric IOL (Alcon Inc Laboratories) implantation were assessed pre- and postoperatively using the NIDEK OPD Scan II (NIDEK Co Ltd). Wavefront aberrometry, corneal topography, and objective visual quality w...
متن کاملComparison of pupil diameter measurement with Lenstar LS 900 and OPD Scan II. Not interchangeable devices.
D pupil measurement is of great concern in corneal refractive surgery, as well as when phakic or multifocal intraocular lens (IOL) implantation is planned.1,2 Pupil size may influence the choice of ablation zone in refractive surgery and IOL design in cataract surgery, and it should be measured accurately so as not to end up with unfavorable postoperative outcomes, such as halos, glare, or poor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 22 9 Suppl شماره
صفحات -
تاریخ انتشار 2006