Predicting fetal acidemia using umbilical venous cord gas parameters.

نویسندگان

  • Jessica Cantu
  • Jeff M Szychowski
  • Xuelin Li
  • Joseph Biggio
  • Rodney K Edwards
  • William Andrews
  • Alan T N Tita
چکیده

OBJECTIVE To assess the utility of umbilical cord venous blood gas measures for prediction of umbilical artery pH and base deficit acidemia. METHODS A retrospective cohort study was conducted of all singletons with valid paired arterial and venous cord gas samples delivered at our institution from January 2006 to March 2012. Fetal acidemia was defined primarily as cord arterial blood gas pH less than 7.0. We also evaluated prediction of acidemia, defined as an arterial base deficit 12 mmol/L or greater. Logistic regression was performed to estimate probabilities of fetal arterial pH and base deficit acidemia given venous blood gas pH or base deficit. Receiver operating characteristic curves were derived to determine predictive ability. Venous blood gas pH and base deficit cutoffs associated with 1% or less, 5%, 10%, and 50% probability of fetal acidemia were identified. RESULTS Of 23,506 births, 11,455 (49%) met criteria for inclusion. The frequency of arterial blood gas pH less than 7.0 was 127 (1.1%); arterial blood gas base deficit 12 mmol/L or greater was 245 (2.1%). Venous blood gas pH (area under the curve [AUC] 0.949, 95% confidence interval [CI] 0.920-0.979; P<.001) and base deficit (AUC 0.969, 95% CI 0.954-0.983; P<.001) were predictors of acidemia based on arterial blood gas pH and base deficit, respectively. Venous blood gas pH cutoffs associated with 1% or less, 5%, or 10% probabilities of arterial blood gas pH less than 7.0 were 7.23, 7.17, and 7.14, respectively. Venous blood gas base deficit values associated with similar probabilities for base deficit 12 mmol/L or greater were 6.3 or less, 8.2 or less, and 9.0 mmol/L or less. For prediction of arterial blood gas pH, adjusting venous blood gas pH for base deficit increased the AUC (0.961, 95% CI 0.938-0.984). Prediction of arterial blood gas base deficit by venous blood gas base deficit was unchanged by adjustment for pH (AUC 0.969, 95% CI 0.955-0.984). CONCLUSION We demonstrate that venous blood gas parameters are powerful predictors of arterial blood gas pH and base deficit and can be used to predict the likelihood of fetal acidemia when the cord arterial blood gas is not available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Umbilical Cord Arterial Blood Gas and Apgar Score: Who Is at Higher Risk?

Background: Fetal asphyxia and the consequent neurological damages could be avoided if the risk factors are controlled at earlier stages. Umbilical cord arterial blood gas (UCABG) seems to be related to the Apgar scores, as well as the neonatal morbidity and mortality rates. Therefore, we designed this study to assess the correlation between the Apgar score and UCABG i...

متن کامل

Stress hormones and acid-base status in human fetuses at term delivery: the effect of delivery method.

To evaluate the effect of delivery mode on fetal stress hormones and acid-base status and also to investigate the relationship between fetal acidemia and these hormones. 64 women with term pregnancies were studied. All had singleton, healthy pregnancies. Twenty one women were delivered by spontaneous vaginal route, 23 by vaginal route following oxytocin infusion and 20 by elective caesarean sec...

متن کامل

ACOG Committee Opinion No. 348, November 2006: Umbilical cord blood gas and acid-base analysis.

Umbilical cord blood gas and acid-base assessment are the most objective determinations of the fetal metabolic condition at the moment of birth. Moderate and severe newborn encephalopathy, respiratory complications, and composite complication scores increase with an umbilical arterial base deficit of 12-16 mmol/L. Moderate or severe newborn complications occur in 10% of neonates who have this l...

متن کامل

Physiological development of a mixed metabolic and respiratory umbilical cord blood acidemia with advancing gestational age.

OBJECTIVE To investigate respiratory and metabolic components of gestational age-dependent umbilical cord blood gas changes. STUDY DESIGN Cord blood gases were determined in 1336 vigorous singletons with uncomplicated cephalic vaginal delivery at 37-43 weeks. Linear regression analysis and non-parametric statistics were used with a P < 0.05 being significant. RESULTS Gestational age correla...

متن کامل

The effect of maternal parameters on umbilical artery blood gas values and neonatal well-being in singleton pregnancies

Objectives. Umbilical cord blood analysis for assessment of the newborn’s acid-base status soon after birth is the most objective way of evaluating the fetal metabolic condition at delivery. We researched the effects of maternal age, multiple gestation, fetal heart rate, gestational age, parity, delivery mode and total duration of labor on fetal well-being as assessed by umbilical cord blood ga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obstetrics and gynecology

دوره 124 5  شماره 

صفحات  -

تاریخ انتشار 2014