Semi-automated scoring of triple-probe FISH in human sperm: methods and further validation.
نویسندگان
چکیده
Although the frequency and consequence of sperm chromosomal abnormalities are considerable, few epidemiologic studies in large samples have been conducted to investigate etiologic risk factors. This is, in part, attributable to the labor intensive demands of manual sperm fluorescence in situ hybridization (FISH) scoring. As part of an epidemiologic study investigating environmental risk factors for aneuploidy among men attending a hospital-based fertility clinic, a semi-automated method of slide scoring was further validated and used to estimate sex chromosome sperm disomy frequency in a large number of samples. Multiprobe FISH for chromosomes X, Y, and 18 was used to determine sex chromosome disomy in sperm nuclei. Semi-automated scoring methods were used to quantify X disomy (sperm FISH genotype XX18), Y disomy (YY18), and XY disomy (XY18). The semi-automated results were compared with the results from manual scoring in 10 slides. The semi-automated method was then used to estimate sex chromosome disomy frequency in 60 men. Of 10 slides scored, significant differences between the manual and semi-automated results were seen primarily in one slide that was of poor quality because of over swollen nuclei. Among 60 men analyzed using the semi-automated method, median total sex chromosome disomy frequency was 1.65%, which is higher than seen among normal men but within range with reports from fertility clinic populations. These results further validate that semi-automated methods can be used to score sperm disomy with results comparable to manual methods. This is the largest study to date to provide estimates of sex chromosome disomy among men attending fertility clinics. These methods should be replicated in larger clinic populations to arrive at stable estimates of aneuploidy frequency in men who are members of subfertile couples. © 2011 International Society for Advancement of Cytometry.
منابع مشابه
Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis
Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT. We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). ...
متن کاملFISH and tips: a large scale analysis of automated versus manual scoring for sperm aneuploidy detection
BACKGROUND Approximately 1% of the spermatozoa found in ejaculate of healthy men are aneuploid and this rate increases in the population of subfertile and infertile men. Moreover, fertilization with these aneuploid sperm can lead to impaired embryo development. Fluorescent In Situ Hybridization (FISH) is the common cytogenetic tool used for aneuploidy screening on sperm. However, it is a time-c...
متن کاملP-11: DHR123: A Suitable Fluorescent Mitochondrial Probe for Assessment of H2O2 in Human Spermatozoa
Background: The objective of present study was to assess potential of DHR123 (dihydrorhodamine 123) fluorescent probe for measurement of H2O2 produced by human spermatozoa and comparing the results with DCFH-DA (2', 7'-dichlorodihydrofluorescein diacetate). Materials and Methods: Fluorescent intensity and percentage R123 and DCF positive sperm measured by flow cytometry. The suitable ...
متن کاملAnalysis of unfertilized oocytes subjected to intracytoplasmic sperm injection using two rounds of fluorescence in-situ hybridization and probes to five chromosomes.
Chromosomal aberrations are the major cause of pre- and post-implantation embryo wastage and some studies suggest that half of all human conception have a chromosomal abnormality. Analysis of gametes provides information on the origin of these chromosomal aberrations. The purpose of this study was to develop a reliable multi-probe fluorescence in-situ hybridization (FISH) procedure that would e...
متن کاملSignal Amplification of FISH for Automated Detection Using Image Cytometry
The purpose of this study was to improve the detection of FISH signals, in order that spot counting by a fully automated image cytometer be comparable to that obtained visually under the microscope. Two systems of spot scoring, visual and automated counting, were investigated in parallel on stimulated human lymphocytes with FISH using a biotinylated centromeric probe for chromosome 3. Signal ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 79 8 شماره
صفحات -
تاریخ انتشار 2011