MAXIPIX, a fast readout photon-counting X-ray area detector for synchrotron applications

نویسنده

  • C. Ponchut
چکیده

A 2D photon-counting X-ray detector system with 1.4 kHz frame rate and 55 μm spatial resolution has been developed and commissionned on ESRF beamlines. The system called MAXIPIX (Multichip Area X-ray detector based on a photon-counting PIXel array) consists of a detector module implementing up to five MEDIPIX-2 or TIMEPIX photon-counting readout chips, a custom readout interface board and a Linux acquisition workstation. The detector module readout time is 290 microseconds, allowing the system to achieve sustained frame rates of 280 Hz to 1400 Hz depending on the number of connected chips. An effective time resolution of 60 ns was measured using the ESRF pulsed modes and a TIMEPIX module. The system architecture and characteristics are presented, as well as a summary of its applications on ESRF beamlines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement...

متن کامل

Improved count rate corrections for highest data quality with PILATUS detectors

The PILATUS detector system is widely used for X-ray experiments at third-generation synchrotrons. It is based on a hybrid technology combining a pixelated silicon sensor with a CMOS readout chip. Its single-photon-counting capability ensures precise and noise-free measurements. The counting mechanism introduces a short dead-time after each hit, which becomes significant for rates above 10(6) p...

متن کامل

Indirectly illuminated X-ray area detector for X-ray photon correlation spectroscopy.

An indirectly illuminated X-ray area detector is employed for X-ray photon correlation spectroscopy (XPCS). The detector consists of a phosphor screen, an image intensifier (microchannel plate), a coupling lens and either a CCD or CMOS image sensor. By changing the gain of the image intensifier, both photon-counting and integrating measurements can be performed. Speckle patterns with a high sig...

متن کامل

A Review of the Applications of Synchrotron Radiation in Archaeological Sciences

The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...

متن کامل

Development of EM-CCD-based X-ray detector for synchrotron applications

Copyright and Moral Rights for the articles on this site are retained by the individual authors and/or other copyright owners. For more information on Open Research Online's data policy on reuse of materials please consult the policies page. We have developed and successfully demonstrated a high speed, low noise camera system for crystallography and X-ray imaging applications. By coupling an EM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011