Application of time-varying analysis to diagnostic needle electromyography.

نویسنده

  • Geoffrey L Sheean
چکیده

Quantification in clinical, diagnostic electromyography (EMG) currently includes motor unit action potential (MUAP) analysis and interference pattern analysis. Early efforts to examine the frequency/power spectra of the interference pattern showed modest value but the technique was not developed further. This paper re-examines spectral analysis, extending it into the time-varying domain, which has never been studied in diagnostic needle EMG. Time-frequency and time-scale analysis employing wavelet and non-wavelet techniques were applied to short trains of MUAPs. The results show that time-varying analysis produces clear visual representations of the energy content of individual MUAPs within an interference pattern. The time frequency representations allow easy, qualitative distinction between normal and neurogenic MUAPs. Furthermore, the quantified MUAP energy correlates well with the current morphological standard and the quantification process is substantially faster. Time-varying analysis links classical power spectral analysis in the realm of interference patterns with quantitative MUAP analysis. In addition to morphological classification, MUAPs might also be classified by energy content, which more closely reflects the physical and physiological consequences of neuromuscular pathology on the motor unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Iran's inflation analysis using varying coefficient model

Varying coefficient Models are among the most important tools for discovering the dynamic patterns when a fixed pattern does not fit adequately well on the data, due to existing diverse temporal or local patterns. These models are natural extensions of classical parametric models that have achieved great popularity in data analysis with good interpretability.The high flexibility and interpretab...

متن کامل

Sub-optimal Estimation of HIV Time-delay Model using State-Dependent Impulsive Observer with Time-varying Impulse Interval: Application to Continuous-time and Impulsive Inputs

Human Immunodeficiency Virus (HIV) weakens the immune system in confronting various diseases by attacking to CD4+T cells. In modeling HIV behavior, the number of CD4+T cells is considered as the output. But, continuous-time measurement of these cells is not possible in practice, and the measurement is only available at variable intervals that are several times bigger than sampling time. In this...

متن کامل

Comparative Evaluation of Cell Block Method and Smear Cytology in Fine Needle Aspiration Cytology of Intra-abdominal Mass Lesions

Background& Objective: Fine needle aspiration cytology (FNAC) is an easy, rapid, and less hazardous tool to diagnose the intra-abdominal lesions with various imaging modalities adding to its sensitivity and accuracy. However, sometimes it does not yield adequate information for precise diagnosis and the risk of false-negative and indeterminate diagnosi...

متن کامل

Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study

Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...

متن کامل

Modeling and Forecasting Iranian Inflation with Time Varying BVAR Models

This paper investigates the forecasting performance of different time-varying BVAR models for Iranian inflation. Forecast accuracy of a BVAR model with Litterman’s prior compared with a time-varying BVAR model (a version introduced by Doan et al., 1984); and a modified time-varying BVAR model, where the autoregressive coefficients are held constant and only the deterministic components are allo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2012