PURPOSE To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). METHODS Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. RESULTS The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. CONCLUSIONS The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +...

متن کامل

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens Cirurgia de cristalino transparente com lente intraocular multifocal asférica difrativa Teresa Ferrer-Blasco1, sanTiago garcía-lázaro1, césar alBarrán-Diego1, lurDes BelDa-salmerón1, roBerT monTés-micó1

The main goal of a presbyopic patient is to reduce dependence on optical aids and improve both distance and near vision as well as the range of clear vision. Several studies report good safety, predictability, and efficacy outcomes in the implantation with monofocal, toric and multifocal intraocular lenses (IOLs) after refractive lens exchange (RLE). Patients with hybrid spherical IOLs show goo...

متن کامل

Design and qualification of a diffractive trifocal optical profile for intraocular lenses.

PURPOSE To theoretically and experimentally assess a new aspheric diffractive trifocal intraocular lens (IOL). SETTING Centre Spatial de Liège, Liège, Belgium. DESIGN Evaluation of diagnostic test or technology. METHODS The theoretical profile of the IOL was designed using software simulation and validated by optical calculation software tools that enabled complete theoretical characteriz...

متن کامل

Quels bénéfices visuels peut-on attendre d’un implant sans aberration sphérique dans la chirurgie de la cataracte ?

Purpose: To assess the quality of vision in pseudophakic patients with aspheric intraocular lens (IOL) without spherical aberration compared to patients with spherical IOL. Methods: Twenty-four patients (48 eyes) undergoing cataract surgery were randomly divided into two groups: 12 patients received an aspheric IOL in both eyes and 12 received spherical IOLs. The integrity of ocular functions w...

متن کامل

Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision.

PURPOSE To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality. SETTING Cathedral Eye Clinic, Belfast, United Kingdom. DESIGN Retrospective comparative case series. METHODS Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2016