An analysis of the accuracy of magnetic resonance flip angle measurement methods.

نویسندگان

  • Glen R Morrell
  • Matthias C Schabel
چکیده

Several methods of flip angle mapping for magnetic resonance imaging have been proposed. We evaluated the accuracy of five methods of flip angle measurement in the presence of measurement noise. Our analysis was performed in a closed form by propagation of probability density functions (PDFs). The flip angle mapping methods compared were (1) the phase-sensitive method, (2) the dual-angle method using gradient recalled echoes (GRE), (3) an extended version of the GRE dual-angle method incorporating phase information, (4) the AFI method and (5) an extended version of the AFI method incorporating phase information. Our analysis took into account differences in required imaging time for these methods in the comparison of noise efficiency. PDFs of the flip angle estimate for each method for each value of true flip angle were calculated. These PDFs completely characterize the performance of each method. Mean bias and standard deviation were computed from these PDFs to more simply quantify the relative accuracy of each method over its range of measurable flip angles. We demonstrate that the phase-sensitive method provides the lowest mean bias and standard deviation of flip angle estimate of the five methods evaluated over a wide range of flip angles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Measurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers

Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...

متن کامل

Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences.

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a widely used technique for assessing tissue physiology. Spoiled gradient echo (SPGR) pulse sequences are one of the most common methods for acquisition of DCE-MRI data, providing high temporal and spatial resolution with strong T(1)-weighting. Conversion of SPGR signal to concentration is briefly reviewed, and a new closed-form ...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 55 20  شماره 

صفحات  -

تاریخ انتشار 2010