Detection of antibodies against HLA-C epitopes in patients with rejected kidney transplants.

نویسندگان

  • Rene J Duquesnoy
  • Marilyn Marrari
چکیده

BACKGROUND Although HLA-C matching is not considered in kidney transplantation, several reports have shown that anti-HLA-C antibodies are associated with rejection and graft failure. DNA-based typing methods can now accurately determine HLA-C compatibility and sensitive assays such as Luminex with single alleles can identify HLA-C antibodies. HLA-C displays considerable amino acid polymorphism that can be translated into a structurally defined epitope repertoire. METHODS We have analyzed post-allograft nephrectomy sera from 45 HLA-C mismatched cases submitted by 15 laboratories worldwide participating in the 15th International Histocompatibility Workshop. All of them had HLA class I antibodies detected by a Luminex-based solid phase method using single-allele beads. This study addressed the determination of antibodies against donor HLA-C mismatches. Analysis of antibody reactivity patterns was performed using HLAMatchmaker, a structurally based matching program that considers 56 HLA-C eplets to define antibody-reactive epitopes. Many eplets shared by groups of HLA-C antigens, whereas others are also shared with HLA-A and/or HLA-B antigens. RESULTS Twenty-seven patients (60%) had donor-specific HLA-C antibodies, significantly less than the donor-specific antibodies induced by HLA-A and HLA-B mismatches. HLA-C antibody responses correlated with the eplet loads of the HLA-C mismatches. There were 352 instances whereby a donor HLA-C eplet was mismatched and for 84 (24%) of them there was antibody reactivity with a particular eplet (69 instances) or an eplet pair (15 instances). The latter generally consisted of mismatched eplets paired with self-eplets shared between the immunizing HLA-C alleles and HLA alleles of the patient. Several HLA-C eplets exhibited a relatively high immunogenicity as evidenced by their frequencies of specific antibodies. CONCLUSION These findings demonstrate the importance of HLA-C mismatching in humoral sensitization and that HLA-C epitopes can induce specific antibodies. They illustrate the usefulness of HLAMatchmaker in understanding donor-specific antibody reactivity patterns and the determination of HLA mismatch acceptability when transplantation is considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anti-HLA Antibodies and Kidney Allograft Outcomes in Recipients with Donor Bone Marrow Cell Infusion

Background: Anti-HLA-antibodies are known to affect the allograft survival in transplant recipient patients. Objective: The aim of this study was to evaluate the association between anti-HLA antibodies and kidney allograft outcomes, particularly in recipients with concur-rent donor bone marrow cell infusion (DBMI). Methods: Between June 2006 and May 2007, forty living unrelated donor kidney tra...

متن کامل

Serum analysis after transplant nephrectomy reveals restricted antibody specificity patterns against structurally defined HLA class I mismatches.

This study deals with HLA-mismatched kidney transplants that have been removed following rejection. Sera from 27 patients were screened for HLA-specific antibodies by direct complement-dependent lymphocytotoxicity with HLA-typed cell panels. Circulating donor-specific antibodies were detected in 3 cases (11%) before and in 26 cases (97%) after allograft nephrectomy. These findings demonstrate t...

متن کامل

Autoantibody response to islet transplantation in type 1 diabetes.

Islet allotransplantation into patients with autoimmune type 1 diabetes represents a reexposure to autoantigen. Here, measurement of antibodies to GAD and IA-2 autoantigens before and after islet transplantation in 36 patients (33 receiving islet plus kidney grafts with cyclosporin and steroid-based immunosuppression, and 3 receiving solitary islet transplants with mycophenolate but cyclosporin...

متن کامل

Detection of donor-specific HLA antibodies before and after removal of a rejected kidney transplant.

UNLABELLED Serum analysis of patients considered for retransplantation has a potential limitation that the rejected allograft may absorb HLA antibodies. We have determined how the highly sensitive micro bead-based Luminex antibody-binding assay with single antigens can detect donor-specific HLA antibodies (DSA) in patients before and after surgical removal of a rejected allograft. This analysis...

متن کامل

A Novel Method for Anti-HLA Antibody Detection Using Personalized Peptide Arrays

BACKGROUND HLA mismatches are the primary cause of alloantibody-mediated rejection (AMR) in organ transplantation. To delineate antigenic and immunogenic potentials among individual HLA mismatches, information regarding antibody specificity at the epitope level, instead of the allelic level, is needed. METHODS This study explores a direct screening method for HLA linear epitopes in kidney tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transplant immunology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2011