Long-term size follow-up of knitted Dacron grafts (Gelseal™) used in the ascending aorta.

نویسندگان

  • Yoshiyuki Takami
  • Kazuyoshi Tajima
  • Wataru Kato
  • Kei Fujii
  • Makoto Hibino
  • Hisaaki Munakata
  • Kenichiro Uchida
  • Yoshimasa Sakai
چکیده

There is limited information about the size change of a knitted Dacron graft (Gelseal™) used in the thoracic aorta. We evaluated the diameters of the Gelseal™ grafts at a long-term follow-up for 3.7 ± 1.3 years (1-5.9 years; median, 4.0 years), which were used for replacement of the ascending aorta in 59 patients with acute aortic dissection. The early and late dilatation rates (LDRs) of the prosthetic grafts were calculated retrospectively based on the graft diameter at the level equivalent to the ascending aorta on the pre-discharge computed tomography (CT) scans and follow-up CT scans performed every year after surgery. Immediately after surgery (15 ± 7 days), the early dilatation of the Gelseal™ grafts was 26.0 ± 6.0% with significant correlations with the number of post-operative days (R = 0.500, P = 0.003). At the follow-up for 3.7 ± 1.3 years, the LDR was 10.5 ± 6.6%, which was also significantly correlated with the number of the post-operative years (R = 0.608, P = 0.001). Linear regression analysis indicated that the annual dilatation rate was ≈ 3.23%. During the follow-up, we have experienced no redo surgery due to graft fracture or false aneurysm formation at the anastomosis sites associated with the graft dilatation. In conclusion, the Gelseal™ graft used in the ascending aorta demonstrates a small but continuous increase in the diameter, up to 5 years after implantation, without any adverse events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of ten clinically used arterial prostheses.

The arterial grafts currently in use are classified into five basic categories; 10 different commercially available prostheses were chosen to represent these categories. The Vascutek and Bionit are made from knitted Dacron and have medium porosity, requiring preclotting by the surgeon. The DeBakey Soft Woven and Plasma TFE grafts are made from woven Dacron and have low porosity, not requiring p...

متن کامل

Old Myths, New Concerns: the Long-Term Effects of Ascending Aorta Replacement with Dacron Grafts. Not All That Glitters Is Gold

Synthetic grafts are widely used in cardiac and vascular surgery since the mid-1970s. Despite their general good performance, inability of mimicking the elastomechanical characteristics of the native arterial tissue, and the consequent lack of adequate compliance, leads to a cascade of hemodynamic and biological alterations deeply affecting cardiovascular homeostasis. Those concerns have been r...

متن کامل

Spontaneous perigraft hematoma suggesting transgraft hemorrhage seven years after thoracic aortic replacement with a Dacron graft.

As a previously unrecognized late graft-related complication, we report a case of spontaneous perigraft hemorrhage, which was evidenced by contrast extravasation on computed tomographic scan seven years after thoracic aortic replacement with a knitted Dacron graft. There was no anastomotic problem or graft tear, and the hematoma seemed to result from transgraft hemorrhage. Inadequate graft heal...

متن کامل

Behaviour of polyester grafts in adult patients with repaired coarctation of the aorta.

AIMS Whatever the technique used for surgical or endovascular repair of a coarctation of the aorta (CA), long-term complications might occur. Aneurysm formation after patch angioplasty is not uncommon and may lead to a life-threatening condition. Therefore, we were interested in the long-term results of different types of tube grafts, from which a lower degree of dilatation is expected. METHO...

متن کامل

Surgical Club of South West England

out ascending bifemoral reconstruction in order to bypass the peritoneal cavity as described by R. J. Baird. In both cases, the femoral arteries were exposed first, to ascertain the adequacy of the run off. This being satisfactory, the ascending aorta was exposed through a median sternotomy. An 8 mm preformed axillo-bifemoral knitted Dacron Graft was pre-clotted and having applied a side occlud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 14 5  شماره 

صفحات  -

تاریخ انتشار 2012