SU-E-T-184: LINAC Commissioning Measurements Utilizing the Cylindrical Arc Check Phantom.
نویسندگان
چکیده
PURPOSE New devices for IMRT and VMAT QA are continually becoming available. Despite the availability of these devices they are underutilized for routine mechanical QA. In this work we take advantage of the cylindrical geometry of the Arc Check phantom to perform tests that are an integral part of commissioning and routine QA. METHODS The Arc Check is a cylindrical phantom with a diameter of 26.59cm and a 1386 diode array arranged on a cylindrical plane. Owing to its cylindrical design it is capable of measuring entry and exit radiation. For this experiment the Arc Check was set up using the mechanical pointer at 86.7cm SSD. The device was leveled using its inclinometer and was properly rotated to align with the lasers and cross-hair. With the phantom set up at the expected isocenter of the LINAC, 100MUs with a 10×10 field were delivered at different gantry angles, couch and collimator rotations. Each delivery was recorded individually and for each one the radiation center at the entry and exit levels of the detector were estimated. That provided the path of the radiation center through the device. The radiation path was reconstructed for each rotation individually and the coincidence of the mechanical and radiation isocenter was evaluated. RESULTS A procedure and MATLAB routine were developed that accepted as input the text files that are the output of the Arc Check measurement and geometrically reconstructed in 3-dimensions the isocenter and radiation central axis for each rotation. The coincidence of the radiation and mechanical isocenter was verified. CONCLUSIONS This work demonstrates that by utilizing the geometry of a commercially available device multiple mechanical LINAC tests that are part of routine QA can be evaluated in one single setup.
منابع مشابه
Operating Experience of the J-PARC Linac
The beam commissioning of the J-PARC linac started in November 2006 and 181 MeV acceleration was successfully achieved in January 2007. The linac has delivered beams to the 3 GeV Rapid Cycling Synchrotron for its commissioning, and then, the subsequent Main Ring Synchrotron and the neutron target commissioning. The linac uses a Cs-free LaB6-driven ion source and 20 units of 324 MHz klystrons. A...
متن کاملSU-E-T-592: Comparison of Low Dose Volume and Integral Dose in Rotational Arc Radiation Therapy Modalities.
PURPOSE To compare low dose volume and integral dose of various rotational arc radiation therapy modalities, including helical tomotherapy (HT) and other volumetric modulated arc therapies (VMAT). METHODS A digital cylindrical phantom and an anthropomorphic pelvic phantom were used in the study. HT treatment was planned on TomoTherapy Planning Station (Accuray) and VMAT plans were generated o...
متن کاملCommissioning of volumetric modulated arc therapy (VMAT) in a dual-vendor environment.
Methods and results for commissioning of the complete VMAT delivery chain are presented for the combination of Nucletron's Oncentra MasterPlan® v3.3 with Elekta's Mosaiq® v1.6 and SynergyS® linac. VMAT specific linac commissioning included determination of the size of the minimal dynamic leaf gap. Dosimetric validation of the complete treatment chain was performed using a 2D-ionization-chamber-...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملImpact of backscattered radiation from the bunker structure on EPID dosimetry
Amorphous silicon electronic portal imaging devices (EPIDs) have been investigated and used for dosimetry in radiotherapy for several years. The presence of a phosphor scintillator layer in the structure of these EPIDs has made them sensitive to low-energy scattered and backscattered radiation. In this study, the backscattered radiation from the walls, ceiling, and floor of a linac bunker has b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part12 شماره
صفحات -
تاریخ انتشار 2012