Relationship between resonance and gas exchange during high frequency jet ventilation.

نویسندگان

  • E S Lin
  • M J Jones
  • S D Mottram
  • B E Smith
  • G Smith
چکیده

We have studied the relationship between gas exchange and mechanical frequency response during high frequency jet ventilation (HFJV) at 0.5-5.0 Hz in anaesthetized pigs. The mechanical gain curve showed a minimal "anti-resonant" response at 0.8 Hz (f1) and a maximal "resonant" response at 5.0 Hz (f2). This finding may be explained by modelling the thorax and abdomen as a system of coupled masses and compliances which undergo two different modes of forced oscillation in the frequency range studied. Gas exchange was optimal in the frequency range between the minimal and maximal responses. The tidal volumes produced were greater than anatomical deadspace, suggesting that gas transport was mainly convective in this range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery

 Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...

متن کامل

RESPIRATION AND THE AIRWAY Frequency dependence of lung volume changes during superimposed high-frequency jet ventilation and high-frequency jet ventilation

Editor’s key points † Superimposed high-frequency jet ventilation (SHFJV) involves simultaneous normal frequency (12–20 min) and high-frequency jet ventilation (HFJV) (.500 min). † SHFJV may improve ventilation and gas exchange compared with HFJValone, but the optimum frequencies for SHFJV are unknown. † In this animal model, end-expiratory and tidal volumes determined by opto-electronic plethy...

متن کامل

Heliox administration during high-frequency jet ventilation augments carbon dioxide clearance.

We report the combined use of heliox and high-frequency jet ventilation to augment carbon dioxide clearance, with a focus on the important technical considerations. Our case is a 5-month old infant with acute respiratory failure associated with gas trapping, hypercarbia, respiratory acidosis, and air leak. Despite maximal conventional ventilation, bronchodilator therapy, corticosteroids, and se...

متن کامل

A comparison of proximal and distal high-frequency jet ventilation in an experimental animal model.

High-frequency jet ventilation using either a proximal or a distal endotracheal injection site through a triple-lumen endotracheal tube was studied in 10 adult cats. The comparative effects on pulmonary gas exchange, tracheal pressure, heart rate, and blood pressure were examined for each injection site at both high (8-12 pounds per square inch [PSI] and low (5-8 PSI) jet-driving pressures in n...

متن کامل

Clinical uses of high frequency jet ventilation in anaesthesia.

Since 1981, high frequency jet ventilation (HFJV) has been used in 300 patients undergoing surgery, most commonly during i.v. general anaesthesia for endoscopy and surgery of the airways: laryngoscopy, bronchoscopy, laryngeal microsurgery and laser surgery (more than 230 patients); repair of tracheal stenosis, tracheal sleeve pneumonectomy and tracheal sleeve lobectomy. HFJV was administered th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 1990