Online preconcentration ICP-MS analysis of rare earth elements in seawater

نویسندگان

  • Ed C. Hathorne
  • Brian Haley
  • Torben Stichel
  • Martin Frank
چکیده

[1] The rare earth elements (REEs) with their systematically varying properties are powerful tracers of continental inputs, particle scavenging intensity and the oxidation state of seawater. However, their generally low ( pmol/kg) concentrations in seawater and fractionation potential during chemical treatment makes them difficult to measure. Here we report a technique using an automated preconcentration system, which efficiently separates seawater matrix elements and elutes the preconcentrated sample directly into the spray chamber of an ICP-MS instrument. The commercially available “seaFAST” system (Elemental Scientific Inc.) makes use of a resin with ethylenediaminetriacetic acid and iminodiacetic acid functional groups to preconcentrate REEs and other metals while anions and alkali and alkaline earth cations are washed out. Repeated measurements of seawater from 2000 m water depth in the Southern Ocean allows the external precision (2s) of the technique to be estimated at <23% for all REEs and <15% for most. Comparison of Nd concentrations with isotope dilution measurements for 69 samples demonstrates that the two techniques generally agree within 15%. Accuracy was found to be good for all REEs by using a five point standard addition analysis of one sample and comparing measurements of mine water reference materials diluted with a NaCl matrix with recommended values in the literature. This makes the online preconcentration ICP-MS technique advantageous for the minimal sample preparation required and the relatively small sample volume consumed (7 mL) thus enabling large data sets for the REEs in seawater to be rapidly acquired.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of rare earth elements in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry.

A home made column of commercially available iminodiacetate resin, Muromac A-1 (50-100 mesh) was used to concentrate rare earth elements (REEs) (15 elements: Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) in seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the dete...

متن کامل

Sample pretreatment using chitosan-based chelating resin for the determination of trace metals in seawater samples by inductively coupled plasma-mass spectrometry.

A sample-pretreatment method using a chitosan-based chelating resin, ethylenediamine-N,N,N'-triacetate-type chitosan (EDTriA-type chitosan), was developed for the preconcentration of trace metals in seawater and separation of the seawater matrix prior to their determination by inductively coupled plasma-mass spectrometry (ICP-MS). The resin showed very good adsorption for transition metals and ...

متن کامل

Preconcentration of ultratrace rare earth elements in seawater with 8-hydroxyquinoline immobilized polyacrylonitrile hollow fiber membrane for determination by inductively coupled plasma mass spectrometry

8-Hydroxyquinoline immobilized on polyacrylonitrile hollow fiber membrane was synthesized and used for the preconcentration of rare earth elements (REEs) and the separation of the matrix in seawater prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS). Both the capacity and chemical stability of the modified polyacrylonitrile hollow fiber membrane have been eval...

متن کامل

Determination of heavy metals and rare earth elements in environmental samples by ICP-MS after solid phase preconcentration with chelating resin fibers and anion exchanger filters.

A solid phase collection/concentration method using anion exchanger filters and a small syringe packed with chelating resin fibers is adopted as a preconcentration tool for trace elements and a separation tool for matrices in aqueous samples prior to the measurement by inductively coupled plasma-mass spectrometry (ICP-MS). The effects of fiber volume, sample volume, eluent volume, and sample fl...

متن کامل

On-line preconcentration system using mini-column packed with a chelating resin for the characterization of seasonal variations of trace elements in seawater by ICP-MS and ICP-AES.

An on-line column preconcentration technique coupled with inductively coupled plasma-mass spectrometry (ICP-MS) and -atomic emission spectrometry (ICP-AES) was developed using a mini-column (ca. 3 mm i.d., 40 mm length), that was packed with chelating resin (0.2 g) of iminodiacetic acid groups, Muromac A-1. After the preconcentration step, the column was washed with ammonium acetate buffer (pH ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012