Quantitative ultrasound for the detection and management of osteoporosis.
نویسندگان
چکیده
Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.
منابع مشابه
Pnm-23: Ultrasound Evaluation of Multiple Pregnancies
Over the past 25 years the rate of twin and higher - order multifetal birth have increased between 1980 and 2005. The twining rate rose from 18.9 to 32.1 per 1000 live birth. Multifetal gestations are at high risk of fetaland complication such as; growth restricted fetal death, LBW and cerebral palasy. Maternal complication are that also increased such as: preeclampsia, diabetes, maternal death...
متن کاملUltrasound Assisted Emulsification Microextraction as a Simple Preconcentration Method for Determination of Atrazine in Environmental Samples
We represent an environmentally friendly sample of pre-treatment method, ultrasound assisted emulsification microextraction (USAEME) followed by gas chromatography nitrogen phosphorous detector (GC-NPD), to specify atrazine residues in environmental samples. Some parameters affecting the extraction efficiency such as the type and volume of the extraction solvent, emulsification time and additio...
متن کاملQuantitative Ultrasound Techniques for the Assessment of Osteoporosis: Expert Agreement on Current Status CLAUS-C. GLÜER FOR THE INTERNATIONAL QUANTITATIVE ULTRASOUND CONSENSUS GROUP*
Quantitative ultrasound (QUS) methods have been introduced in recent years for the assessment of skeletal status in osteoporosis. The performance of QUS techniques has been evaluated in a large number of studies. Reviewing existing knowledge, an international expert panel formulated the following consensus regarding the current status of this technology. To date, evidence supports the use of QU...
متن کاملAssessment of Osteoporosis in Family Medicine Obtained by Ultrasound Densitometry
INTRODUCTION Osteoporosis is a disease characterized by a decrease in bone mineral density, making bones become less rigid, and therefore susceptible to fractures, either spontaneously or with force, which is lower than otherwise needed for healthy bones fractured. Nearly 10% of the world population and 30% of women after menopause, suffer from osteoporosis. Clinical assessment of osteoporosis ...
متن کاملUltrasound Assisted Surfactant Enhanced Emulsification Microextraction and Spectrofluorimetry for Determination of Oxadiazon in Agricultural Water Samples
In this work, an environmentally friendly sample pre-treatment method, Ultrasound Assisted Surfactant Enhanced Emulsification Microextraction (UASEME) followed with spectrofluorimetry was performed for determination of oxadiazon residues in water samples. After the determination of the most suitable extraction solvent and its volume, other parameters such as type and concentration of surfac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Salud publica de Mexico
دوره 51 Suppl 1 شماره
صفحات -
تاریخ انتشار 2009