Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

نویسندگان

  • A T Edmunds
  • S Godfrey
  • M Tooley
چکیده

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher than indirect Fick measurements of cardiac output, but after application of a correction factor related to packed cell volume there was close correlation between the results obtained by the two methods (r = 0.94). 3. The mean coefficient of variation of impedance measurements of cardiac output was 13% at rest and 5% during steady-state exercise. 4. Changes of lung volume due to breath holding or resulting from addition of an expiratory resistance did not affect the measurement of cardiac output by impedance. 5. Transthoracic impedance cardiography is a rapid, non-invasive technique for measurement of cardiac output. It requires very little active co-operation from the subject. The method would probably give reliable results for patients with respiratory illnesses such as acute asthma or bronchiolitis, during which changes of lung volume may be expected to occur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impedance cardiography for monitoring changes in cardiac output.

Impedance Cardiography (ICG) is a non invasive method useful for continuous monitoring of cardiac output but, it still has not found wide usage for measuring cardiac output in clinics and research. Most studies focused on comparing the cardiac output measured at rest with reference methods. In the present study we evaluated the validity of ICG against Doppler Echocardiography (DE) in measuring ...

متن کامل

Pulmonary Congestion at Rest and Abnormal Ventilation During Exercise in Chronic Systolic Heart Failure

BACKGROUND In patients with chronic heart failure, abnormal ventilation at cardiopulmonary testing (expressed by minute ventilation-to-carbon dioxide production, or VE/VCO2 slope, and resting end-tidal CO2 pressure) may derive either from abnormal autonomic or chemoreflex regulation or from lung dysfunction induced by pulmonary congestion. The latter hypothesis is supported by measurement of pu...

متن کامل

Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.

Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...

متن کامل

Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output.

BACKGROUND Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained by magnetic resonance imaging, are available. OBJECTIVE To evaluate the performance of transthoracic impedance cardiography in the ca...

متن کامل

Enhanced muscle pump during mild dynamic leg exercise inhibits sympathetic vasomotor outflow

Muscle sympathetic nerve activity (MSNA) is not increased during leg cycling at light and mild intensities, despite activation of central command and the exercise pressor reflex. We determined whether increasing central blood volume and loading the cardiopulmonary baroreceptors modulate sympathetic vasomotor outflow during leg cycling. To this end, we changed the pedaling frequency to enhance s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 63 2  شماره 

صفحات  -

تاریخ انتشار 1982