Indication of direct acoustical cochlea stimulation in comparison to cochlear implants
نویسندگان
چکیده
The new implantable hearing system Codacs™ was designed to close the treatment gap between active middle ear implants and cochlear implants in cases of severe-to-profound mixed hearing loss. The Codacs™ actuator is attached to conventional stapes prosthesis during the implantation and thereby provides acoustical stimulation through a stapedotomy to the cochlea. Cochlear implants (CIs) on the other hand are an established treatment option for profoundly deaf patients including mixed hearing losses that are possible candidates for the Codacs™. In this retrospective study, we compared the clinical outcome of 25 patients with the Codacs™ (≥3 month post-activation) to 54 CI patients (two years post-activation) with comparable pre-operative bone conduction (BC) thresholds that were potential candidates for both categories of devices. The word recognition score (Freiburg monosyllables test) in quiet was significantly (p < 0.05) better in the Codacs™ than in the corresponding CI patients for average pre-operative bone conduction below 60 dB HL and equal in patients with a pre-operative BC PTA between 60 and 70 dB HL. Speech in noise intelligibility (HSM sentences test at +10 dB SNR) was significantly (p < 0.001) better in Codacs™ (80% median) than in CI patients (25% median) in all tested groups. Our results indicate for patients with sufficient cochlear reserve that speech intelligibility in noise with the Codacs™ hearing implant is significantly better than with a CI. Further, results in Codacs™ were better predictable, encouraging the extension of the indication to patients with less cochlear reserve than reported here.
منابع مشابه
Detection of pulse trains in the electrically stimulated cochlea: effects of cochlear health.
Perception of electrical stimuli varies widely across users of cochlear implants and across stimulation sites in individual users. It is commonly assumed that the ability of subjects to detect and discriminate electrical signals is dependent, in part, on conditions in the implanted cochlea, but evidence supporting that hypothesis is sparse. The objective of this study was to define specific rel...
متن کاملLateralization of interaural timing differences with multi-electrode stimulation in bilateral cochlear-implant users.
Bilateral cochlear implant (BiCI) users have shown variability in interaural time difference (ITD) sensitivity at different places along the cochlea. This paper investigates perception of multi-electrode binaural stimulation to determine if auditory object formation (AOF) and lateralization are affected by variability in ITD sensitivity when a complex sound is encoded with multi-channel process...
متن کاملRobotically Assisted Cochlear Imaging and Access 600
Cochlear implants are electronic devices that are used to restore hearing to individuals with severe-toprofound sensorineural loss via direct stimulation of the auditory nerve. Implantation requires the insertion of an electrode into human cochlea. This project aims at developing a safe robotic approach for minimizing intracochlear trauma during electrode insertion and consequently preserving t...
متن کاملRobotically Assisted Cochlear Imaging and Access
Cochlear implants are electronic devices that are used to restore hearing to individuals with severe-to-profound sensorineural loss via direct stimulation of the auditory nerve. Implantation requires the insertion of an electrode into human cochlea, which is associated with several challenges and severe complications. In this study, a new approach is developed that incorporates the cooperative ...
متن کاملThe Importance of Human Cochlear Anatomy for the Results with Modiolus Hugging Multi-Channel Cochlear Implants
Hypothesis: The fact that the anatomy of the basal turn of the human cochlea, especially, is essentially different from that of other species is likely to influence the outcome of cochlear implantation. Background: Multichannel cochlear implants give better speech understanding than single-channel devices. They are intended to make use of the tonotopic organization of the cochlea by selectively...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hearing Research
دوره 340 شماره
صفحات -
تاریخ انتشار 2016