Microfluidic temperature gradient focusing.
نویسندگان
چکیده
A new technique is described for the concentration and separation of ionic species in solution within microchannels or capillaries. Concentration is achieved by balancing the electrophoretic velocity of an analyte against the bulk flow of solution in the presence of a temperature gradient. With an appropriate buffer, the temperature gradient can generate a corresponding gradient in the electrophoretic velocity, so that the electrophoretic and bulk velocities sum to zero at a unique point, and the analyte will be focused at that point. The technique is demonstrated for a variety of analytes, including fluorescent dyes, amino acids, DNA, proteins, and particles, and is shown to be capable of greater than 10,000-fold concentration of a dilute analyte.
منابع مشابه
Taylor-Aris dispersion in temperature gradient focusing.
Microfluidic temperature gradient focusing (TGF) uses an axial temperature gradient to induce a gradient in electrophoretic flux within a microchannel. When balanced with an opposing fluid flow, charged analytes simultaneously focus and separate according to their electrophoretic mobilities. We present a theoretical and experimental study of dispersion in TGF. We model the system using generali...
متن کاملBallistic dispersion in temperature gradient focusing
Molecular dispersion is caused by both molecular diffusion and non-uniform bulk fluid motion. While the Taylor–Aris dispersion regime is the most familiar regime in microfluidic systems, an oft-overlooked regime is that of purely kinematic (or ballistic) dispersion. In most microfluidic systems, this dispersion regime is transient and quickly gives way to Taylor–Aris dispersion. In electrophore...
متن کاملMicrofluidic two-dimensional separation of proteins combining temperature gradient focusing and sodium dodecyl sulfate-polyacrylamide gel electrophoresis.
A two-dimensional separation system is presented combining scanning temperature gradient focusing (TGF) and sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis (PAGE) in a PDMS/glass microfluidic chip. Denatured proteins are first focused and separated in a 15 mm long channel via TGF with a temperature range of 16-47 °C and a pressure scanning rate of -0.5 Pa/s and then further sepa...
متن کاملNumerical Study of Droplet Generation Process in a Microfluidic Flow Focusing
Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...
متن کاملA Review of Heating and Temperature Control in Microfluidic Systems: Techniques and Applications
This review presents an overview of the different techniques developed over the last decade to regulate the temperature within microfluidic systems. A variety of different approaches has been adopted, from external heating sources to Joule heating, microwaves or the use of lasers to cite just a few examples. The scope of the technical solutions developed to date is impressive and encompasses fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 74 11 شماره
صفحات -
تاریخ انتشار 2002