Thallium-201 gated single-photon emission tomography for assessing left ventricular volumes and function in patients with aortic valve stenosis: Comparison with echocardiography as the reference standard

نویسندگان

  • Satoshi Kurisu
  • Toshitaka Iwasaki
  • Hiroki Ikenaga
  • Noriaki Watanabe
  • Tadanao Higaki
  • Takashi Shimonaga
  • Ken Ishibashi
  • Naoya Mitsuba
  • Yoshihiro Dohi
  • Yasuki Kihara
چکیده

BACKGROUND Aortic valve stenosis (AS) is characterized by chronic left ventricular pressure overload, leading to left ventricular hypertrophy (LVH). We assessed correlations in left ventricular volumes and function between echocardiography and quantitative gated SPECT (QGS) in patients with AS. METHODS AND RESULTS The study population consisted of 28 patients with AS defined as a peak velocity of > 3.0 m/s and 28 age- and sex-matched control subjects. Patients with AS had a peak pressure gradient of 73.4 ± 24.5 mm Hg and a larger LVM index compared to control subjects (115.5 ± 29.2 g/m2 vs 78.3 ± 12.1 g/m2, p < 0.01). There were good correlations in end-diastolic volume and end-systolic volume between echocardiography and QGS in patients with AS as well as control subjects. Bland-Altman plot for end-systolic volume showed a significant negative slope of - 0.51 in patients with AS. There was a good correlation in ejection fraction between the 2 methods in patients with AS as well as control subjects. However, Bland-Altman plots showed significant negative slopes of - 0.40 in patients with AS and - 0.74 in control subjects. CONCLUSIONS Our data suggested that QGS was a useful method for assessing left ventricular volumes and function even in patients with AS. Cardiologists should recognize its specific characteristics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Physiologic Assessment of Coronary Artery Stenosis by Coronary Flow Reserve Measurements With Transthoracic Doppler Echocardiography: Comparison With Exercise Thallium-201 Single-Photon Emission Computed Tomography

OBJECTIVES We evaluated the value of coronary flow reserve (CFR), as determined by transthoracic Doppler echocardiography (TTDE), for physiologic assessment of coronary artery stenosis severity, and we compared TTDE measurements with those obtained by exercise thallium201 (Tl-201) single-photon emission computed tomography (SPECT). BACKGROUND Coronary flow reserve measurements by TTDE have been...

متن کامل

A Comparison of Thallium-201 Spect and F-18 Deoxyglucose Positron Emission Tomography in Assessing Myocardial Viability

Assessment of myocardial viability 1>rior to revascularization procedures is an important clinical consideration for improved functional recovery of regional left ventricular dysfunction. In chronic coronary artery disease, impaired left ventricular function , at least in part, is due to ischemic or hibernating myocardium rather than just myocardial fibrosis. Functional recovery of the left ven...

متن کامل

Low-dose dobutamine echocardiography and rest-redistribution thallium-201 tomography in the assessment of spontaneous recovery of left ventricular function after recent myocardial infarction.

Spontaneous improvement of contraction and perfusion occurs after acute myocardial infarction. The relative merit of low-dose dobutamine stress echocardiography (LDDE) and rest-redistribution thallium scintigraphy (RR TI) in this setting has not been evaluated. We studied 30 patients at 7 +/- 3 days after acute myocardial infarction with LDDE (5 to 10 micrograms/kg/min) and RR TI single photon ...

متن کامل

Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease.

BACKGROUND The phenomenon of reversible impairment in LV function has been well described and is known as myocardial stunning. OBJECTIVE Thallium-201 myocardial perfusion gated SPECT was used to evaluate myocardial stunning and its incremental prognostic value in patients with coronary artery disease. PATIENTS AND METHODS Fifty-six patients (aged 63+/-11 years) with coronary artery disease ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2014