Comparison of sequentially measured Aloka echo-tracking one-point pulse wave velocity with SphygmoCor carotid-femoral pulse wave velocity.

نویسندگان

  • Olga Vriz
  • Caterina Driussi
  • Salvatore La Carrubba
  • Vitantonio Di Bello
  • Concetta Zito
  • Scipione Carerj
  • Francesco Antonini-Canterin
چکیده

OBJECTIVES Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral pulse wave velocity higher than 12 m/s. METHODS A total of 160 consecutive subjects (112 male/48 female, mean age = 51.5 ± 14.1 years; 96 healthy, 44 hypertensives, 13 with aortic valve disease, and 7 with left ventricular dysfunction) were studied. Carotid-femoral pulse wave velocity was measured with the SphygmoCor system and one-point carotid pulse wave velocity with high-definition echo-tracking system (ProSound Alpha10; Aloka, Tokyo, Japan). RESULTS Both carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity correlated significantly with each other (r = 0.539, p < 0.001) and with age (one-point carotid pulse wave velocity r = 0.618, carotid-femoral pulse wave velocity r = 0.617, p < 0.0001 for both). Median value of carotid-femoral pulse wave velocity (7.2 m/s, 95% confidence interval = 6.2-8.9) was systematically higher than that of one-point carotid pulse wave velocity (5.8 m/s, 95% confidence interval = 5-6.6). The area under the receiver operating characteristic curve was 0.85, identifying the cutoff for one-point pulse wave velocity of 6.65 m/s as the best predictor of carotid-femoral pulse wave velocity more than 12 m/s (sensitivity = 0.818, specificity = 0.819). CONCLUSIONS One-point carotid pulse wave velocity correlates with carotid-femoral pulse wave velocity, and the cutoff of 6.65 m/s was the best predictor of carotid-femoral pulse wave velocity over 12 m/s.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of pulse wave velocity in children: comparison of volumetric and tonometric sensors, brachial-femoral and carotid-femoral pathways

BACKGROUND Pulse wave velocity (PWV), a measure of arterial stiffness strongly predictive of cardiovascular risk in adults, is usually measured by sequential ECG-referenced carotid and femoral tonometry. A simplified technique, more suitable for use in children, employs simultaneous volumetric recording from a sensor applied over the carotid artery and a cuff applied over the femoral artery or ...

متن کامل

Evaluation of carotid-femoral pulse wave velocity: influence of timing algorithm and heart rate.

Carotid-femoral pulse wave velocity (PWV), a measure of arterial stiffness, is determined from the time taken for the arterial pulse to propagate from the carotid to the femoral artery. Propagation time is measured variously from the foot of the waveform or point of maximum upslope. We investigated whether these methods give comparable values of PWV at rest, during beta-adrenergic stimulation, ...

متن کامل

Carotid-femoral pulse wave velocity assessment using novel cuff-based techniques: comparison with tonometric measurement.

BACKGROUND Carotid-femoral pulse wave velocity, a predictor of cardiovascular outcome, is conventionally measured using a tonometer sequentially placed upon the carotid and femoral arteries, gated using an electrocardiogram. Leg cuff detection of the femoral pulse removes the need for signal gating, reduces the time required for a single measurement, but gives different pulse wave velocity valu...

متن کامل

Measurement of Aortic Pulse Wave Velocity With a Connected Bathroom Scale

BACKGROUND Measurement of arterial stiffness should be more available. Our aim was to show that aortic pulse wave velocity can be reliably measured with a bathroom scale combining the principles of ballistocardiography (BCG) and impedance plethysmography on a single foot. METHOD The calibration of the bathroom scale was conducted on a group of 106 individuals. The aortic pulse wave velocity w...

متن کامل

Aortic stiffness predicts functional outcome in patients after ischemic stroke.

BACKGROUND AND PURPOSE Increased aortic stiffness (measured by carotid-femoral pulse wave velocity) and central augmentation index have been shown to independently predict cardiovascular events, including stroke. We studied whether pulse wave velocity and central augmentation index predict functional outcome after ischemic stroke. METHODS In a prospective study, we enrolled 99 patients with a...