Development of a method to determine Ni and Cd in biodiesel by graphite furnace atomic absorption spectrometry

نویسندگان

  • Fabiana A. Lobo
  • Danielle Goveia
  • Adriana P. Oliveira
  • Luciane P.C. Romão
  • Leonardo F. Fraceto
  • Newton L. Dias Filho
  • André H. Rosa
چکیده

This paper proposes a low cost, simple, fast method for determining Ni and Cd in biodiesel samples by graphite furnace atomic absorption spectrometry (GFAAS). The method was evaluated in biodiesel from different sources. Tungsten was used as a permanent modifier and the samples were prepared in the form of microemulsions, by mixing about 0.5 g of biodiesel with 5 g of surfactant (Triton X-100) in volumetric flasks and completing the volume with HNO3 1% (v/v). The detection limits obtained for Ni and Cd in microemulsions were 60.9 and 0.1 lg L , respectively. The relative standard deviation (% R.S.D., n = 12) was 68.20% for Ni (washed animal fat sample) and 64.71% for Cd (sunflower oil sample). Accuracy was checked based on addition and recovery experiments, which yielded recovery rates varying from 93% to 108% for Ni and from 98% to 116% for Cd. Sample preparation is rapid and easy, and the use of an inorganic standard for calibration makes this sample preparation procedure suitable for routine applications. 2010 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Collection and preparation of sidestream cigarette smoke for trace elemental determinations by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry.

A novel method for the collection and preparation of sidestream cigarette smoke condensate is described for trace elemental analysis by inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry. The smoke collection method utilizes a specially designed chimney that collects and directs the sidestream smoke (SS) to a 2-stage trapping system consisting of an...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Determination of trace elements in aqua regia and nitric acid digests

This Horizontal Standard includes principles and procedures for the determination of trace metals in aqua regia and nitric acid digests of sludge, soil and treated biowaste and neighbouring samples, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable for determination of low concentrations of the following elements: Ag, Cd, Co, Cr...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010