Background Myocardial CT perfusion is a relatively new technique which enables the assessment of perfusion deficits through first pass imaging in combination with pharmacological stress. Comparison of CT and MR perfusion has been limited and in-vivo assessment is affected by physiological variability, acquisition timing during firstpass contrast perfusion and parameter selection. We utilized a myocardial perfusion phantom to precisely compare high resolution k-t SENSE MR perfusion with single phase CT perfusion under identical imaging conditions.
منابع مشابه
A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
BACKGROUND Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. METHODS We use...
متن کاملPerfusion Phantom: An Efficient and Reproducible Method to Simulate Myocardial First-Pass Perfusion Measurements with Cardiovascular Magnetic Resonance
The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملFeasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom
Background: PET-MR scanners are beginning to be employed for quantitative myocardial perfusion imaging. In order to examine simultaneous perfusion calculations, this work describes a feasibility study of simultaneous PET-MR of gadolinium-based contrast agent (GBCA) and PET radiotracer in a novel cardiac perfusion phantom. Results: [F]F and GBCA were injected simultaneously into a cardiac phanto...
متن کاملCovid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT
A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...