Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

نویسندگان

  • Antonio Benito
  • Guillermo M Pérez
  • Sandra Mirabet
  • Meritxell Vilaseca
  • Jaume Pujol
  • José M Marín
  • Pablo Artal
چکیده

PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film breakup was performed in eyes with mild dry-eye symptoms (study group) and in an asymptomatic control group. Series of consecutive retinal images were recorded every 0.5 seconds while the patient avoided blinking. Measurements were performed under low-light conditions to naturally increase pupil diameter and maximize the method's sensitivity. Additional clinical tests were performed for comparison and included tear breakup time (TBUT), Schirmer I tests, and a normalized questionnaire (McMonnies). From the retinal images, a quality metric, the intensity distribution index, was calculated. An objective TBUT value was estimated in each eye when the intensity distribution index surpassed a defined threshold value compared with the initial baseline. RESULTS The study group comprised 20 eyes and the control group, 18 eyes. Symptomatic dry eyes had a typical exponential increase in the intensity distribution index with time. The objective TBUT values in the study group were comparable to the clinical TBUT estimates. CONCLUSIONS The new objective optical method to evaluate the quality and stability of the tear film was sensitive in detecting mild symptoms of dry eye and differentiating from normal cases. The procedure may allow early detection and follow-up of patients' tear film-related complaints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of the tear film in the optical quality of the human eye.

This paper reviews recent studies of the role of the tear film in the optical quality of the eye. Recent investigations focus on the dynamics of the tear film after a blink and its important role in the optical quality of the eye. The results in this review were used in an attempt to understand the optical and visual impact of tear-film breakup in normal eyes and dry eyes. It was noted that pat...

متن کامل

Assessment of Tear Film Optical Quality Dynamics.

PURPOSE To investigate tear film optical quality dynamics by analyzing the postblink temporal changes of objective scatter index (OSI). METHODS A total of 109 myopic subjects without symptoms of dry eye and 32 myopic subjects diagnosed with dry eye disease were recruited in this cross-sectional study. The right eye for each subject was analyzed. Serial measurements of OSI were performed for 2...

متن کامل

Dynamic changes in the tear film in dry eyes.

PURPOSE To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film. METHODS Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All d...

متن کامل

The importance of the precorneal tear film for the quality of optical imaging.

The optical function of the eye critically depends on the presence of an intact precorneal tear film. Abnormalities of the tear film such as those occurring in the dry eye syndrome or in otherwise irritated eyes may interfere with vision. In 30 patients with dry eyes artificial tears were found to produce statistically significant improvement of vision (p less than 0.001) while no significant c...

متن کامل

Effect of Airflow Exposure on the Tear Meniscus

Purpose. To compare the effect of airflow exposure on the tear meniscus and blink frequency in normal and evaporative dry eye subjects. Methods. In 9 normal subjects and 9 short tear breakup time (SBUT) dry eye subjects, lower tear meniscus height (TMH) and area (TMA) and blink frequency were measured with anterior segment optical coherence tomography (OCT) before and after 5 minutes of airflow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2011