Micellar medium for the analysis of complex mixtures of molybdenum and tungsten by derivative synchronous spectrofluorimetry in steels.
نویسندگان
چکیده
The cationic surfactant hexadecyltrimethylammonium bromide enhances the fluorescence intensity of both molybdenum and tungsten complexes obtained with Alizarin Red S. This characteristic has been used for a sensitive simultaneous spectrofluorimetric determination of both ions over the range 32-4000 ng/ml and 49-2500 ng/ml for Mo and W, respectively. Good selectivity is achieved applying the well known synchronous derivative technique with a minucious pH selection. The proposed method has been applied to a certified steel sample with recoveries between 96 and 102%.
منابع مشابه
Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملComparison of doped combination zirconium-tungsten, zirconium- molybdenum and molybdenum-tungsten on single-wall vanadium oxide nanotube in hydrogen gas adsorption
In this study, doped vanadium oxide nanotubes were evaluated using different software to study the absorption of hydrogen gas. Vanadium oxide nanotubes are one of the options for absorption and storage hydrogen gas. In this research study for the first time, the Monte Carlo simulation was used to investigate the hydrogen gas absorption behavior in molybdenum-tungsten, molybdenum-zirconium and z...
متن کاملSimultaneous determination of binary mixtures of sulfonylurea herbicides in water by first-derivative photochemically induced spectrofluorimetry.
First-derivative photochemically induced spectrofluorimetry (PIF-1D) is applied to the simultaneous determination of binary mixtures of 4 sulfonylurea herbicides in aqueous micellar samples. Synthetic binary mixtures of sulfometuronmethyl with chlorsulfuron, metsulfuron-methyl, and 3-rimsulfuron, respectively, are well resolved by using the zero-crossing point procedure. PIF-1D allows the deter...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملThree-dimensional synchronous fluorescence spectrometry for the analysis of three-component alkaloid mixtures.
A study of a simple and sensitive method for the determination of berberine, luguine and sanguinarine in mixtures by normal and synchronous derivative spectrofluorimetry is described. The influence of solvents and other experimental variables is discussed. A three-dimensional plot of both emission-excitation and synchronous spectra obtained by a new software program provides additional informat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 42 8 شماره
صفحات -
تاریخ انتشار 1995