Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip.
نویسندگان
چکیده
BACKGROUND We compared the accuracy and practicability of a new combined ear sensor device measuring pulse oximetry and transcutaneous carbon dioxide tension. METHODS Validation studies were done by comparing the results of the combined sensor with arterial blood gas measurements. In an observational part, monitoring data were obtained from 25 patients undergoing colonoscopy, sedated with midazolam and alfentanil and from 8 patients without sedation. RESULTS There was an excellent correlation between the oxygen saturation and carbon dioxide tension measurements comparing the combined sensor with arterial blood gas analysis (R 0.96 and 0.93, respectively). A mean rise in transcutaneous carbon dioxide tension of 7.6 mm Hg was detectable during sedation with midazolam/alfentanil and of 2.3 mm Hg without sedation. CONCLUSION Combined POX/PcCO2 monitoring at the ear lobe is a novel approach to improve patient safety during sedation and may be helpful in preventing an unintentional slide into a state of deep sedation with impairment of ventilation.
منابع مشابه
Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy.
The aim of the present study was to assess the feasibility of measuring combined arterial oxygen saturation measured by pulse oximetry (Sp,O2) and cutaneous carbon dioxide tension (Pc,CO2) to monitor ventilation and quantify change in Pc,CO2 during bronchoscopy. Combined Sp,O2 and Pc,CO2 were measured at the ear lobe in 114 patients. In four patients, the ear-clip slipped and they were excluded...
متن کاملCombined oximetry-cutaneous capnography in patients assessed for long-term oxygen therapy.
STUDY AIM To evaluate the feasibility of combined oximetry (pulse oximetric saturation [Spo(2)]) and cutaneous capnography (transcutaneous carbon dioxide tension [Ptcco(2)]) for oxygen titration in patients requiring long-term oxygen therapy. METHODS Twenty patients with obstructive or restrictive lung disease underwent oxygen titration using a combined cutaneous oximetry-capnography sensor. ...
متن کاملHemodynamic patterns of blunt and penetrating injuries.
BACKGROUND The aims of this prospective observational study were to describe early hemodynamic patterns of blunt and penetrating truncal injury and to evaluate outcomes prediction using noninvasive hemodynamic monitoring with a mathematical model tested against actual in-hospital outcomes. The hypothesis was that traumatic shock is a circulatory disorder that can be monitored by noninvasive hem...
متن کاملMonitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.
OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or he...
متن کاملCapnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy.
BACKGROUND Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Digestion