An X-ray microsource based system for crystal screening and beamline development during synchrotron shutdown periods.

نویسندگان

  • Mitchell D Miller
  • Ashley M Deacon
چکیده

Crystallographic end-stations require a significant investment in state-of-the-art equipment, as well as a significant effort in software development. The equipment often sits idle during annual maintenance shutdowns. In order to utilize the existing hardware and software during these shutdowns, we installed a sealed-tube microsource X-ray generator in the beamline 9-2 hutch at Stanford Synchrotron Radiation Laboratory. A multi-layer optic provides good flux and spectral purity. The small physical size of the source, the long optic to focus distance (635 mm) and the short source to optic distance (65 mm) allowed the use of existing beamline components, without any significant modification. The system replaces a short section of beam pipe upstream of the beam conditioning slits and shutter. The system can be installed and removed from the beamline in less than 1 day.The Joint Center for Structural Genomics (JCSG) and SSRL Structural Molecular Biology group developed the Stanford Automated Mounting (SAM) system and installed it on beamlines at SSRL. The JCSG relies on this system to test crystals for diffraction. The installation of the X-ray microsource in beamline 9-2 allowed crystal screening to continue during SSRL shutdowns. Using a standard screening protocol of two 10 minute exposures, separated by a 90° phi rotation, the system was capable of screening up to 400 crystals per week and was left to run unattended for up to 4 days. Over 8200 crystals were screened during the last four SSRL shutdown periods.An X-ray generator can also be useful for ongoing beamline development. Shutdown periods provide easier access to the experimental hardware, however, some tests require beam. The X-ray microsource offers the ability to conduct these tests during periods when users are not scheduled.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angle Dispersive X-ray Diffraction Beamline on Indus-2 Synchrotron Radiation Source: Commissioning and First Results

Angle dispersive x-ray diffraction (ADXRD) is a basic non destructive tool for the determination of crystal structure. Energy tunability and high flux are added advantages in using synchrotron radiation (SR) source for ADXRD technique. We have installed an ADXRD beamline (BL-12) on Indus-2, the Indian synchrotron source. Indus-2 is a 2.5GeV, 300mA SR source. The beamline consists of a Si (311) ...

متن کامل

Development of a differential pumping system for soft X-ray beamlines for windowless experiments under normal atmospheric conditions.

A novel design for a differential pumping system has been investigated. This system allows windowless experiments in a soft X-ray beamline under normal atmospheric conditions. The new design consists of an aperture-based four-stage differential pumping system, based on a simple model calculation. A prototype system with a total length of 600 mm was constructed to confirm the validity of the des...

متن کامل

Detection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study

Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...

متن کامل

Beamline X29: a novel undulator source for X-ray crystallography.

A high-flux insertion device and beamline for macromolecular crystallography has been built at the National Synchrotron Light Source (NSLS) that employs a mini-gap undulator source developed by the NSLS. The mini-gap undulator at beamline X29 is a hybrid-magnet device of period 12.5 mm operating at proven gaps of 3.3-10 mm. The beamline provides hard X-rays for macromolecular crystallography ex...

متن کامل

Single-crystal Raman spectroscopy and X-ray crystallography at beamline X26-C of the NSLS

Three-dimensional structures derived from X-ray diffraction of protein crystals provide a wealth of information. Features and interactions important for the function of macromolecules can be deduced and catalytic mechanisms postulated. Still, many questions can remain, for example regarding metal oxidation states and the interpretation of `mystery density', i.e. ambiguous or unknown features wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment

دوره 582 1  شماره 

صفحات  -

تاریخ انتشار 2007