Injection of transient faults using electromagnetic pulses -Practical results on a cryptographic system-

نویسندگان

  • Amine Dehbaoui
  • Jean-Max Dutertre
  • Bruno Robisson
  • P. Orsatelli
  • Philippe Maurine
  • Assia Tria
چکیده

This article considers the use of magnetic pulses to inject transient faults into the calculations of a RISC micro-controller running the AES algorithm. A magnetic coil is used to generate the pulses. It induces computational faults without any physical contact with the device. The injected faults are proved to be constant (i.e. data independent) under certain experimental conditions. This behaviour, combined with the ability to choose the faulted bytes thanks to timing accuracy in the fault injection process, makes it possible to implement most of the state-ofthe-art fault attack schemes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BADFET: Defeating Modern Secure Boot Using Second-Order Pulsed Electromagnetic Fault Injection

Numerous Electromagnetic Fault Injection (EMFI) techniques have been used to attack FPGAs, ASICs, cryptographic devices, and microcontrollers. Unlike other classes of fault injection techniques, EMFI-based attacks can, in theory, be carried out non-invasively without requiring physical contact with the victim device. Prior research has demonstrated the viability of EMFIbased attacks against rel...

متن کامل

Application of Signal Processing Tools for Fault Diagnosis in Induction Motors-A Review-Part II

The use of efficient signal processing tools (SPTs) to extract proper indices for the fault detection in induction motors (IMs) is the essential part of any fault recognition procedure. The 2nd part of this two-part paper is, in turn, divided into two parts. Part two covers the signal processing techniques which can be applied to non-stationary conditions. In this paper, all utilized SPTs for n...

متن کامل

هینه‌سازی مسیر‌ هاد‌ی‌های انتقال در محفظه فلزی تجهیزات الکتریکی مبتنی بر سازگاری الکترومغناطیسی با استفاده از روش تصمیم‌گیری چند معیاره مطالعه موردی: سیستم تزریق جریان 25 کیلو آمپر

The higher frequency transient signals generated as a result of a power system fault or disturbance provide the basis for an alternative approach to power system containing connectors and cables result in unsuitable operation of the system. However one major challenge is the need to ensure that the transients to be neutralized by electromagnetic compatibility (EMC) issues and cabling routes. T...

متن کامل

Differential Fault Analysis

This report presents the results of the Differential Fault Analysis (DFA) Project. The project was funded by Secure Business Austria (SBA) and A-SIT. Its objective was to perform basic steps in the field of fault injection. The effect of faults was investigated in theory as well as in practice. The first part of this report concentrates on theoretical fault models. New fault attacks on public k...

متن کامل

One Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage

This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IACR Cryptology ePrint Archive

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012