Requirements of Clic Beam Loss Monitoring System

نویسنده

  • M. Sapinski
چکیده

The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Requirements of a Beam Loss Monitoring System for the Clic Two Beammodules

The Compact Linear Collider (CLIC) study investigates the feasibility of a high-energy electron-positron linear collider optimized for a centre of mass energy of 3 TeV. To achieve the high accelerating gradients, the RF power is produced by a novel two-beam acceleration method in which a decelerating drive beam supplies energy to the main accelerating beam. The linacs are arranged in modular st...

متن کامل

A Versatile Beam Loss Monitoring System for Clic

The design of a potential CLIC beam loss monitoring (BLM) system presents multiple challenges. To successfully cover the 48 km of beamline, ionisation chambers and optical fibre BLMs are under investigation. The former fulfils all CLIC requirements but would need more than 40000 monitors to protect the whole facility. For the latter, the capability of reconstructing the original loss position w...

متن کامل

Development of a Beam Loss Detection System for the CLIC Test Facility 3

The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6μs electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transient...

متن کامل

Position Resolution of Optical Fibre-based Beam Loss Monitors Using Long Electron Pulses

Beam loss monitoring systems based on optical fibres (oBLM), have been under consideration for future colliders for several years. To distinguish losses between consecutive quadrupoles, the position resolution of detected losses is required to be less than 1 m. A resolution of better than 0.5 m has been achieved in machines with single, short pulses of the order of a nanosecond. In the case of ...

متن کامل

Cern – European Organization for Nuclear Research

The feasibility of a CLIC-LHC based FEL-nucleus collider is investigated. It is shown that the proposed scheme satisfies all requirements of an ideal photon source for the Nuclear Resonance Fluorescence method. The physics potential of the proposed collider is illustrated for a beam of Pb nuclei. Particle Accelerator Conference (PAC'05), Knoxville, Tennessee, USA, May 16-26 2005 Geneva, Switzer...

متن کامل