Bionic Leg Prosthesis Emulates Biological Ankle Joint during Walking

نویسندگان

  • Alena Grabowski
  • Susan D’Andrea
  • Hugh Herr
چکیده

Figure 1. The bionic prosthesis’ mass of 2.0 kg is equivalent to a biological foot and partial shank of an 80 kg person. The prosthesis includes a carbonfiber in-series leaf spring, unidirectional parallel leaf spring, and heel and forefoot leaf springs that provide elasticity. A series-elastic actuator performs negative and positive work. The actuator is comprised of a 200-Watt DC brushless motor and ball screw transmission in series with a carboncomposite leaf spring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation.

Over time, leg prostheses have improved in design, but have been incapable of actively adapting to different walking velocities in a manner comparable to a biological limb. People with a leg amputation using such commercially available passive-elastic prostheses require significantly more metabolic energy to walk at the same velocities, prefer to walk slower and have abnormal biomechanics compa...

متن کامل

Design and Testing of a Bionic Dancing Prosthesis

Traditionally, prosthetic leg research has focused on improving mobility for activities of daily living. Artistic expression such as dance, however, is not a common research topic and consequently prosthetic technology for dance has been severely limited for the disabled. This work focuses on investigating the ankle joint kinetics and kinematics during a Latin-American dance to provide unique m...

متن کامل

Individual Leg and Joint Work during Sloped Walking for People with a Transtibial Amputation Using Passive and Powered Prostheses

People with a transtibial amputation using passive-elastic prostheses exhibit reduced prosthetic ankle power and push-off work compared to non-amputees and compensate by increasing their affected leg (AL) hip joint work and unaffected leg (UL) ankle, knee, and hip joint and leg work during level-ground walking. Use of a powered ankle–foot prosthesis normalizes step-to-step transition work durin...

متن کامل

Multifunctional above-knee prosthesis for stairs' walking.

The multifunctional above-knee prosthesis WLP-7R (Waseda Leg Prosthesis - type 7 Refined) described in this study allows amputees to descend and ascend stairs with no external power sources. With the hydraulic circuit mounted in the shank, the ankle joint and the knee joint mutually conterbalance during stance phase in stair walking as well as level walking so that the following performances ar...

متن کامل

Initial Experimental Study on Dynamic Interaction Between an Amputee and a Powered Ankle-Foot Prostheses

Today, commercially available ankle-foot prostheses are completely passive, and consequently, their mechanical properties remain fixed with walking speed and terrain. Conversely, normal human ankle stiffness varies within each gait cycle and also with walking speed [1][2][3]. Furthermore, some studies have indicated that one of the main functions of the human ankle is to provide adequate energy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011