Microleakage and interfacial morphology of self-etching adhesives in class V resin composite restorations.

نویسندگان

  • Raquel Osorio
  • Manuel Toledano
  • Guillermo de Leonardi
  • Franklin Tay
چکیده

The purpose of the study was to evaluate the marginal leakage of three adhesive systems in Class V resin composite restorations. Two adhesive systems containing acidic primers: Clearfil SE Bond (CSEB) and Etch & Prime 3.0 (E&P), were compared with a conventional water-based primer: Scotchbond Multipurpose Plus (SBMP). Class V cavities were made at the cementum-enamel junction of extracted human molars, which were then divided between three groups. One of the adhesive systems was applied to each group following manufacturers' instructions. Composite restorations were placed, light cured for 40 s, and polished. Specimens were then immersed in a solution of 2% basic fuchsin dye for 24 h. Longitudinal sections were obtained and studied with a stereomicroscope for assessment of the microleakage according to the degree of dye penetration (scale of 0-3). Data were analyzed by Kruskal-Wallis one-way ANOVA, Mann-Whitney tests, and the Wilcoxon matched-pairs signed rank test. Two specimens for each group were analyzed by scanning-electron microscopy (SEM). Bonded interfaces of dentin were also examined by transmission-electron microscopy (TEM). On enamel, there were no significant differences between the three groups. On dentin, CSEB showed the lowest dye penetration values among the three adhesive systems. SEM and TEM studies showed hybrid layer and resin tag formations in all groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

Microleakage and Resin-to-Dentin Interface Morphology of Pre-Etching versus Self-Etching Adhesive Systems

The purpose of this study was to compare the microleakage and tissue-adhesive interface morphology from Class V restorations using different systems of dentin adhesives. Class V cavities were prepared on buccal surfaces of 27 extracted caries-free molars and premolars. Teeth were randomly assigned to one of three groups: (1) Prime & Bond NT, a 5(th) generation system using an initial step of to...

متن کامل

Microleakage of class V resin composites using various self-etching adhesives: an in vitro study.

BACKGROUND AND AIMS Microleakage has been identified as a significant problem with composite restorations because of interfacial gap formation which can result in tooth discoloration, recurrent caries, possible pulpal involvement and restoration replacement. Aim of this study is to evaluate the microleakage of self-etch adhesive system at the coronal and apical margins of class V resin composit...

متن کامل

Microleakage of Composite Resin Restorations Using a Type of Fifth and Two Types of Seventh Generations of Adhesive Systems: A Comparative Study

Introduction: In recent dentin adhesive systems etching of enamel/dentin are achieved simultaneously. The objective was to evaluate the microleakage of composite restorations using Single Bond2 (5th generation), Clearfil S3 Bond and G Bond (7th generation). Methods: Class V cavities were prepared on  45 extracted intact premolars with gingival margins at the cementoenamel junction and they were...

متن کامل

Interfacial integrity of bonded restorations with self-etching adhesives: Water storage and thermo-mechanical cycling

OBJECTIVES OBJECTIVE To evaluate the effect of thermo-mechanical cycling (TMC) on the microleakage (μL) and axial gap width (AG) of Class V bonded restorations in premolars using self-etching adhesive systems. The bond strength of composite restorations to dentin (μTBS) using the same adhesives was also evaluated in third molars after water storage: 24 h and 6 months. The research hypotheses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 66 1  شماره 

صفحات  -

تاریخ انتشار 2003