Optimized chromatographic conditions for separation of halogenated acetic acids by ultra-performance liquid chromatography-electrospray ionization-mass spectrometry.
نویسندگان
چکیده
Emerging halogenated acetic acids (HAAs), especially mixed halogenated acids such as chlorobromo-, chloroiodo- and bromoiodo-acetic acids, are unregulated disinfection by-products in drinking water. Because these compounds are hydrophilic and strongly acidic, they are difficult to detect at trace levels using approved analytical methods. In the present study, 13 HAAs were effectively separated on three ultra-performance liquid chromatography columns. The effects of changing in the aqueous mobile phase, acidic solutions and cationic volatile ion pair reagents were investigated. The samples were pretreated by filtration, and extraction, while derivatization and concentration procedures were not required. The limits of quantitation for regulated HAAs were between 0.5 μg/L and 1.7 μg/L and for unregulated HAAs were 1.2 and 5.8 μg/L, especially for the iodinated acetic acids were 1.5 and 2.1 μg/L. The method was applied to two finished water samples collected in China (Shanghai and Xuzhou) from water treatment plants that use chlorine for disinfection. Multiple unregulated HAAs were found in the two samples, but iodoacids were only detected in the water sample from Shanghai, which could be attributed to the characteristics of the source water. The presence of unregulated HAAs, especially mixed bromo- and iodoacetic acids, in the finished water samples could affect human health, and this warrants further investigation.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملimultaneous determination of puerarin, daidzein, baicalin, wogonoside and iquiritin of GegenQinlian decoction in rat plasma by ultra-performance liquid hromatography–mass spectrometry
A specific ultra-performance liquid chromatography–mass spectrometry (UPLC–MS) method was developed for the simultaneous determination of puerarin, daidzein, baicalin, wogonoside and liquiritin in rat plasma. Chromatographic separation was performed on a C18 column packed with 1.7 m particles by a linear gradient elution. The analytes and carbamazepine (internal standard, I.S.) were monitored i...
متن کاملSeparation and identification of corticosterone metabolites by liquid chromatography--electrospray ionization mass spectrometry.
High-performance liquid chromatography coupled to atmospheric pressure ionization-electrospray ionization mass spectrometry (API-ESI-MS) was investigated for the analysis of corticosterone metabolites; their characterization was obtained by combining the separation on Zorbax Eclipse XDB C18 column (eluted with a methanol-water-acetic acid gradient) with identification using positive ion mode AP...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1277 شماره
صفحات -
تاریخ انتشار 2013