AssayR: A Simple Mass Spectrometry Software Tool for Targeted Metabolic and Stable Isotope Tracer Analyses
نویسندگان
چکیده
Metabolic analyses generally fall into two classes: unbiased metabolomic analyses and analyses that are targeted toward specific metabolites. Both techniques have been revolutionized by the advent of mass spectrometers with detectors that afford high mass accuracy and resolution, such as time-of-flights (TOFs) and Orbitraps. One particular area where this technology is key is in the field of metabolic flux analysis because the resolution of these spectrometers allows for discrimination between 13C-containing isotopologues and those containing 15N or other isotopes. While XCMS-based software is freely available for untargeted analysis of mass spectrometric data sets, it does not always identify metabolites of interest in a targeted assay. Furthermore, there is a paucity of vendor-independent software that deals with targeted analyses of metabolites and of isotopologues in particular. Here, we present AssayR, an R package that takes high resolution wide-scan liquid chromatography-mass spectrometry (LC-MS) data sets and tailors peak detection for each metabolite through a simple, iterative user interface. It automatically integrates peak areas for all isotopologues and outputs extracted ion chromatograms (EICs), absolute and relative stacked bar charts for all isotopologues, and a .csv data file. We demonstrate several examples where AssayR provides more accurate and robust quantitation than XCMS, and we propose that tailored peak detection should be the preferred approach for targeted assays. In summary, AssayR provides easy and robust targeted metabolite and stable isotope analyses on wide-scan data sets from high resolution mass spectrometers.
منابع مشابه
Application of Stable Isotope-Assisted Metabolomics for Cell Metabolism Studies
The applications of stable isotopes in metabolomics have facilitated the study of cell metabolisms. Stable isotope-assisted metabolomics requires: (1) properly designed tracer experiments; (2) stringent sampling and quenching protocols to minimize isotopic alternations; (3) efficient metabolite separations; (4) high resolution mass spectrometry to resolve overlapping peaks and background noises...
متن کاملMetabolome-Wide Analysis of Stable Isotope Labeling—Is It Worth the Effort?
Stable isotope assisted metabolomics techniques have emerged as a valuable tool in systems biology for metabolic flux analysis and pathway discovery (Duckwall et al., 2013; Chokkathukalam et al., 2014; Niedenführ et al., 2015). Traditionally, stable isotope labeling analyses have been highly targeted, meaning that isotopic enrichment of only a small set of metabolites has been analyzed to deduc...
متن کاملNTFD—a stand-alone application for the non-targeted detection of stable isotope-labeled compounds in GC/MS data
SUMMARY Most current stable isotope-based methodologies are targeted and focus only on the well-described aspects of metabolic networks. Here, we present NTFD (non-targeted tracer fate detection), a software for the non-targeted analysis of all detectable compounds derived from a stable isotope-labeled tracer present in a GC/MS dataset. In contrast to traditional metabolic flux analysis approac...
متن کاملMIA: non-targeted mass isotopolome analysis
UNLABELLED MIA detects and visualizes isotopic enrichment in gas chromatography electron ionization mass spectrometry (GC-EI-MS) datasets in a non-targeted manner. It provides an easy-to-use graphical user interface that allows for visual mass isotopomer distribution analysis across multiple datasets. MIA helps to reveal changes in metabolic fluxes, visualizes metabolic proximity of isotopicall...
متن کاملIsotopologue ratio normalization for non-targeted metabolomics.
Robust quantification of analytes is a prerequisite for meaningful metabolomics experiments. In non-targeted metabolomics it is still hard to compare measurements across multiple batches or instruments. For targeted analyses isotope dilution mass spectrometry is used to provide a robust normalization reference. Here, we present an approach that allows for the automated semi-quantification of me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 89 شماره
صفحات -
تاریخ انتشار 2017