Comparison of technetium-99m sestamibi and thallium-201 retention characteristics in canine myocardium.

نویسندگان

  • P G Melon
  • R S Beanlands
  • T R DeGrado
  • N Nguyen
  • N A Petry
  • M Schwaiger
چکیده

OBJECTIVES The aim of this study was to compare the myocardial retention of technetium-99m (Tc-99m) sestamibi and thallium-201 over a wide range of blood flow at different time points after tracer injection. BACKGROUND Technetium-99m sestamibi has been proposed as a new perfusion tracer with better physical characteristics than those of thallium-201 for scintigraphic imaging. However, no studies have simultaneously compared the ability of both tracers to assess myocardial blood flow during pharmacologic vasodilation. METHODS The myocardial retention of Tc-99m sestamibi and thallium-201 were compared over a wide range of blood flow induced by regional coronary occlusion and dipyridamole infusion in an open chest dog model. Myocardial retention of both tracers was determined by in vitro tissue counting at 2, 5, and 20 min after tracer injection and was correlated with microsphere-determined blood flow. RESULTS Thallium-201 demonstrated greater absolute tissue retention than did Tc-99m sestamibi. At 2 min after tracer injection, there was an almost linear relation between the retention of both tracers and myocardial blood flow over a wide flow range. However, this relation was not maintained over time. At 20 min after injection, the retention of both tracers underestimated myocardial blood flow at higher flow rates. At 2, 5 and 20 min after injection, increments of relative tracer retention between the different levels of flow were always greater for thallium-201 than for Tc-99m sestamibi. CONCLUSIONS Thallium-201 displays more suitable physiologic characteristics as a flow tracer and may allow better differentiation of myocardial regions with different levels of coronary flow reserve. For both tracers, early cardiac imaging may minimize underestimation of blood flow at higher flow rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tc-99m MDP, thallium-201 chloride and Tc-99m MAG3 renal uptake in subacute and chronic radiation nephritis compared.

The authors present a comparison of the findings for thallium-201 (Tl-201), Tc-99m MAG3 and Tc-99m MDP in subacute and chronic radiation nephritis in a 9-yr-old boy who was treated by radiation therapy for alveolar rhabdomyosarcoma of the left chest wall by a radiation port that partially included the left kidney. Tl-201 imaging three and six months later showed a cortical defect in the left ki...

متن کامل

The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2...

متن کامل

Resurrection of thallium-201 for myocardial perfusion imaging.

a D t t H w l c T t l t a e 9 2 r t c A i “ e 9 n a s t s r m m p i Thallium-201 has several virtues as a myocardial perfusion agent. It is one of the best of the soluble agents for measuring regional myocardial perfusion, because it has a blood clearance half-time of 30 s and a first pass extraction in the myocardium of 88% (1) (compared with the 1-min blood clearance half-time [2] and 50% to ...

متن کامل

Effects of adenosine and a selective A2A adenosine receptor agonist on hemodynamic and thallium-201 and technetium-99m-sestaMIBI biodistribution and kinetics.

OBJECTIVES The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. BACKGROUND The clinical application of vasodilator stress for perfusion imaging requires consider...

متن کامل

Myocardial perfusion scintigraphy.

Myocardial perfusion scintigraphy (MPS) is the only widely available method of direct assessment of myocardial perfusion. It involves intravenous injection of small amounts of a radioactive tracer at peak stress, followed by imaging of the heart with a gamma camera. There are three commercially available tracers: thallium-201 and two technetium-labelled tracers, sestamibi and tetrofosmin. All t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 1992