Benzodiazepine findings in blood and urine by gas chromatography and immunoassay.

نویسندگان

  • I Rasanen
  • M Neuvonen
  • I Ojanperä
  • E Vuori
چکیده

Gas chromatography (GC) and immunoassay techniques applied to blood and urine specimens were compared for the screening of benzodiazepines in postmortem forensic toxicology. Five hundred and six such successive postmortem cases in which both urine and peripheral blood was sent for toxicological analysis by the medical examiners were selected. The urine specimens were tested by the Emit((R)) d.a.u. Benzodiazepine Assay, and in parallel, the blood and urine specimens were screened for benzodiazepine drugs and their metabolites by an established automated dual-column GC method. The lowest number of positives (153) was obtained when immunoassay was performed without enzyme hydrolysis. When urine samples were hydrolysed before immunoassay, the number of positives increased to 175. The highest number of positives (200) was obtained in urine by GC, and the screening of blood by GC yielded 185 quantitative results. Despite the urine GC screening produced the most positives, the quantitative screening of the blood by GC appears to be the most efficient approach in postmortem forensic toxicology, considering the fact that although urine findings confirm the presence of the drug, quantitative results in urine are irrelevant to acute toxicity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative screening for benzodiazepines in blood by dual-column gas chromatography and comparison of the results with urine immunoassay.

A dual-column retention index method is described for quantitative gas chromatographic (GC) screening of 26 benzodiazepine drugs and metabolites in the blood using DB-5 and DB-17 capillary columns and electron capture detection. The method involves a one-step, small-scale liquid-liquid extraction with ethyl acetate and derivatization with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide w...

متن کامل

Evaluation of four immunoassay screening kits for the detection of benzodiazepines in urine.

The identification of benzodiazepines (BZD) in biological fluids can be a challenging process. The large number of various BZD in pharmaceutical distribution, with similar core structures, and individual metabolic profiles all contribute to a complicated and time-consuming analysis. The purpose of the current study was to evaluate the performance of four commercially available immunoassay urine...

متن کامل

Benzodiazepines identified by capillary gas chromatography-mass spectrometry, with specific ion screening used to detect benzophenone derivatives.

We developed algorithms for confirmation and identification of benzodiazepines and their metabolites, initially detected in urine samples by enzyme-multiplied immunoassay (EMIT). These algorithms are based on the pattern of benzophenone derivatives of benzodiazepines obtained by gas chromatography-mass spectrometry (GC-MS) with use of a modified specific ion selection mode. Benzophenone derivat...

متن کامل

LC-(TOF) MS analysis of benzodiazepines in urine from alleged victims of drug-facilitated sexual assault.

The present study employs a recently reported liquid chromatography-(time of flight) mass spectrometry procedure for the simultaneous analysis of 22 benzodiazepines in human urine specimens. The analysis focused on the most commonly prescribed benzodiazepines and/or their metabolites. Using this method, the limit of quantitation for the benzodiazepines tested ranged from 2 to 10 ng/mL, while th...

متن کامل

Rapid, direct enzyme immunoassay of 11-keto-thromboxane B2 in urine, validated by immunoaffinity/gas chromatography-mass spectrometry.

We have developed a direct enzyme immunoassay (EIA) for quantifying immunoreactive 11-keto-thromboxane B2 (iKTXB) in unprocessed human urine. Cross-reactivity with other thromboxane metabolites and prostanoids was negligible. Analytical recovery of 11-keto-TXB2 in urine specimens was 97.4% to 99.8%. Total imprecision for two clinical specimens was 8.5% and 12.2%. Intake of acetylsalicylic acid ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Forensic science international

دوره 112 2-3  شماره 

صفحات  -

تاریخ انتشار 2000